INSTALLATION
IMPORTANT INSTALLATION
INSTRUCTIONS
The appliance can be installed with just one
lateral wall (to the right or left of the hob),
higher than the hob and positioned at a
minimum distance as indicated in figure 6.
Moreover, the rear wall and the surfaces
adjacent to and surrounding the hob must
resist an temperature of 90 ºC.
The glue which joins the plastic laminate to the
unit must be able to resist temperatures of at
least 150 °C to prevent the coating from
becoming unstuck.
The appliance must be installed in compliance
with the indications of the standards in force.
This appliance is not connected to a device for
the evacuation of the combust products.
Consequently it must be connected in
compliance with the installation instructions
mentioned earlier. Particular attention must be
paid to the information on ventilation and
aeration provided below.
5) VENTILATION
The room where the appliance is installed must be
permanently ventilated to guarantee its correct
operation. The amount of air necessary is that
required for the correct combustion of gas and the
ventilation of the room, which must measure at
least 20 m
3
. The natural airflow must take place
directly through permanent openings made in the
walls of the room to be ventilated, which lead
outside and have a minimum section of 100 cm
2
(see fig. 1). These openings must be made so that
they cannot be blocked.
Indirect ventilation is also allowed by drawing in air
from rooms next to that to be ventilated, absolutely
observing the indications of the standards in force.
CAUTION: if the burners of the cooking top are
without safety thermocouple, the ventilation
outlet must have a minimum 200 cm² section.
6) POSITIONING AND AERATION
Gas hobs must always eliminate the products of
combustion through hoods connected to
chimneys, flues or directly outside (see fig. 2). If it
is not possible to fit a hood, a fan installed in a
window or an outside wall can be used
simultaneously with the appliance (see fig. 3), as
long as the provisions concerning ventilation listed
in the standards in force are strictly observed.
36
Содержание CGW LUX 60 TC 4G AI AL CI
Страница 18: ...REGULACIÓNYTRANSFORMACIÓN OPERACIONES MEDIDAS tarjeta electrónica agujeros 18 ...
Страница 23: ...DATOS TÉCNICOS DE LA REGULACIÓN DEL GAS DEL EQUIPO 23 ...
Страница 42: ...REGULATION AND TRANSFORMATION OPERATIONS MEASUREMENTS electronic card 42 holes ...
Страница 47: ...TECHNICAL DATA OF THE APPLIANCE GAS REGULATION 47 ...
Страница 65: ...65 OPÉRATIONS DE RÉGLAGE ET DE TRANSFORMATION MESURES carte électronique trous ...
Страница 87: ... ΙΑΣΤΑΣΕΙΣ ηλεκτρονική κάρτα τρύπες ΜΕΤΑΤΡΟΠΕΣ 87 ...
Страница 110: ...110 MEDIDAS placa electrónica REGULAÇÕES buracos ...
Страница 116: ...116 ...