INSTALLATION
7) GAS CONNECTION
Before connecting the appliance, ensure that
the data on the label applied to the lower part
is compatible with that of the gas distribution
network.
A printed label of this booklet and one applied
to the underside of the hob indicate the
instructions for regulating the appliance: type
of gas and working pressure.
When the gas is distributed through channels,
the appliance must be connected to the gas
delivery system:
●with hard steel piping compliant with the
standards in force, the joints of which must be
made using threaded fittings compliant
with EN 10226.
●with copper piping compliant with the standards
in force, the joints of which must be made using
mechanical seal fittings compliant with the
standards in force.
●with continuous wall stainless steel flexipipe,
compliant with the standards in force, with a
maximum extension of 2 metres and seals
compliant with the standards in force. This pipe
must be installed so that it cannot come into
contact with the moving parts of the module it is
built into (drawers for instance) and must not
cross compartments that can be filled.
When the gas is delivered directly from a
bottle,
the appliance, fed with a pressure regulator
compliant with the standards in force must be
connected:
●with copper piping compliant with the standards
in force, the joints of which must be made using
mechanical seal fittings compliant with the
standards in force.
●With continuous wall stainless steel flexipipes,
compliant with the standards in force, with a
maximum extension of 2 metres and seals
compliant with the standards in force. This pipe
must be installed so that it cannot come into
contact with the moving parts of the module it is
built into (drawers for instance) and must not
cross compartments that can be filled. We advise
the application of a special adapter (easily
available on the market) to the flexipipe, to
facilitate the connection with the hose support of
the pressure regulator mounted on the bottle.
When the connection is complete, check that it is
perfectly sealed, using a soapy solution and never
a flame.
WARNINGS:
- remember that the gas entry fitting of the
appliance is a 1/2” threaded conic gas male
fitting compliant with EN 10226.
- The appliance is compliant with the
indications of the following European
Directives:
CEE 2009/142 + 93/68 in relation to gas
safety.
37
Содержание CGW LUX 60 TC 4G AI AL CI
Страница 18: ...REGULACIÓNYTRANSFORMACIÓN OPERACIONES MEDIDAS tarjeta electrónica agujeros 18 ...
Страница 23: ...DATOS TÉCNICOS DE LA REGULACIÓN DEL GAS DEL EQUIPO 23 ...
Страница 42: ...REGULATION AND TRANSFORMATION OPERATIONS MEASUREMENTS electronic card 42 holes ...
Страница 47: ...TECHNICAL DATA OF THE APPLIANCE GAS REGULATION 47 ...
Страница 65: ...65 OPÉRATIONS DE RÉGLAGE ET DE TRANSFORMATION MESURES carte électronique trous ...
Страница 87: ... ΙΑΣΤΑΣΕΙΣ ηλεκτρονική κάρτα τρύπες ΜΕΤΑΤΡΟΠΕΣ 87 ...
Страница 110: ...110 MEDIDAS placa electrónica REGULAÇÕES buracos ...
Страница 116: ...116 ...