INSTALLATION
FIG. 6
FIG. 7
TECHNICAL INFORMATION
FOR FITTERS
Installation and all the regulation,
transformation and maintenance operations
listed in this section must be carried out
exclusively by qualified personnel.
The appliance must be correctly installed in
conformity with current law and the
manufacturer's instructions.
Incorrect installation may cause injury to
people or animals, or damage to items, for
which the manufacturer cannot be held
responsible.
Throughout the life of the system, the devices
for the safety and automatic regulation of the
appliances must only be modified by the
manufacturer or the duly authorised supplier.
INDICATIONS FOR INSTALLATION
●The device is designed to remain operational for
less than 24 h (non-permanent operating system).
When this limit is reached, a regulation stoppage
occurs so the device can check its efficiency.
●This automatic device is a safety device and must
not be altered. Interference with this device will
eliminate any responsibility by the manufacturer
and invalidate the warranty.
●Observe the national and European standards
applicable (e.g., EN 60335-1/EN 50165) in
relation to electrical safety.
●Before entry into operation, check the wiring
carefully: incorrect wiring may damage the device
and jeopardise the safety of the system.
●Connect and disconnect the hob only after cutting
off the electricity supply.
●Avoid exposing the device to drops of water.
●Avoid laying the valve wires along with the high
voltage wires of the ignition transformer.
●Ensure that there is nothing on the hob,
particularly on the area of the control panel, before
switching on.
●After switching on the hob, wait a few seconds to
complete the automatic calibration procedure of
the control panel.
●In the event of a “partial” short circuit or insufficient
insulation between the line and earth, the voltage
on the sensor electrode may be reduced so much
that it causes the device to lock, due to the
impossibility to sense the flame signal.
●The extra low voltage (ELV) circuit is not safe to
touch (only main insulation in compliance with
EN 60730-1), so the installation must guarantee
the level of protection against electric shock
equivalent to double insulation for the user
interface.
A
B
C
D
E
4F (60)
553
475
62.5 62.5 55 min.
5F (90)
833
475
62.5 62.5 55 min.
IMPORTANT:
a perfect installation, adjustment or
transformation of the cook top to use other
gases requires a QUALIFIED INSTALLER: a
failure to follow this rule will void the
warranty.
MEASUREMENTS TO OBSERVE (in mm)
34
Содержание CGW LUX 60 TC 4G AI AL CI
Страница 18: ...REGULACIÓNYTRANSFORMACIÓN OPERACIONES MEDIDAS tarjeta electrónica agujeros 18 ...
Страница 23: ...DATOS TÉCNICOS DE LA REGULACIÓN DEL GAS DEL EQUIPO 23 ...
Страница 42: ...REGULATION AND TRANSFORMATION OPERATIONS MEASUREMENTS electronic card 42 holes ...
Страница 47: ...TECHNICAL DATA OF THE APPLIANCE GAS REGULATION 47 ...
Страница 65: ...65 OPÉRATIONS DE RÉGLAGE ET DE TRANSFORMATION MESURES carte électronique trous ...
Страница 87: ... ΙΑΣΤΑΣΕΙΣ ηλεκτρονική κάρτα τρύπες ΜΕΤΑΤΡΟΠΕΣ 87 ...
Страница 110: ...110 MEDIDAS placa electrónica REGULAÇÕES buracos ...
Страница 116: ...116 ...