background image

Smart active foam generator 

i

foam

27-32

maintenance and care

TEINNOVA stocks spare parts for all the machine’s components as well as consumables for all the 
maintenance tasks shown in this manual.

If you need any part or consumable, please contact TEINNOVA Customer Service.

Spare Parts:

941445056

941445056

Содержание TEGRAS ifoam

Страница 1: ...user manual EN Smart active foam generator ifoam Original manual translation...

Страница 2: ...gy We offer the option of providing companies with specific training in the use of our equipment and to educate their operators so they provide the best service and thus contribute to the success of t...

Страница 3: ...32 contents symbols used safety warnings conditions of use know your machine control panel remote control accessories and related equipment operating instructions use of chemical products 5 32 6 32 7...

Страница 4: ...generator ifoam 4 32 contents transport maintenance and care waste management troubleshooting guide technical specifications guarantee conditions declaration of conformity CE 25 32 26 32 28 32 29 32...

Страница 5: ...instructions given are not followed properly Make sure you read all the instructions in the Safety information section WARNING This symbol warns you of a potentially dangerous situation that could res...

Страница 6: ...the machine stable Everybody who uses this equipment must be properly trained Mechanical protection gloves and an overall should be worn when using the equipment Full face protection equipment must b...

Страница 7: ...ods It can be used together with a TEGRAS FORTE or TEGRAS MULTIPRO or with a manual lance AR20 Compressed air generator IFOAM PRO Active foam generator and rinser TEGRAS MULTIPRO Pneumatic duct cleani...

Страница 8: ...t wheel 5 Side Cover 6 Transport handle 7 Lance and pistol grip 8 Rear wheel 9 Nozzle compartment 10 Chemical compartment 11 Mains water inlet 12 High pressure outlet 13 Low pressure outlet 14 Lance s...

Страница 9: ...am generator ifoam 9 32 control panel 1 2 3 Main control panel Main Switch Touch Screen Emergency Stop Button Turning the equipment on and off Emergency stop The equipment is controlled using the touc...

Страница 10: ...he instal lation has been continuously maintained Brushing Machine Mode Rinsing Option Activates the rinsing system Modo Lanza Manual Stop Stops all operational systems Foaming Option Activates the ac...

Страница 11: ...ras Multipro brushing machine centring system Controls the machine s foaming function Controls the machine s low pressure rinse function Operates the Tegras brushing machine motor so that its rotation...

Страница 12: ...th standard connectors specifically for supplying high pressure liquids to the high pressure lance supplied by Teinnova The connectors match those used by the TEINNOVA equipment Code AC3303220 8 meter...

Страница 13: ...pressure rinsing nozzles Nozzle for high pressure water injection with a dispersal angle of 25 This nozzle can be found in the upper rear part of the equipment Code 370002505 Green high pressure rins...

Страница 14: ...ode AC6200005 Adapter for connecting the mains water hose to un threaded round taps Code AC6200004 Adapter for connecting the mains water hose to square taps Code AC6200003 Chemical for dissolving gre...

Страница 15: ...art active foam generator ifoam 15 32 accessories and related equipment Pneumatic duct cleaning brushing machine Code TG3310102 Pneumatic duct cleaning brushing machine Code TG3310203 Related equipmen...

Страница 16: ...r different taps which are offered as optional accessories Connect the hose to your IFOAM water inlet connector Steps for a correct ifoam installation Connection to the water supply Connection to main...

Страница 17: ...go into hibernation mode it will not operate and it will display a high water temperature warning on the control screen operating instructions Steps for a correct ifoam installation Inlet temperature...

Страница 18: ...a connector located in the lower rear part of the equipment The connection and disconnection must be done with the equipment switched off Connect the high pressure hose to the high pressure lance To...

Страница 19: ...pressure manual lance Once the lance and pistol grip assembly is connected the correct nozzle is fitted for the required water dispersal angle These nozzles can be found in the upper rear of the equi...

Страница 20: ...ith both devices turned off Connect the low pressure hose to the Tegras brushing machine liquid inlet connector Make sure the tap for the Tegras equipment supply is shut off while the connection is be...

Страница 21: ...hown in the figure Remove the cut out from the Bag in box where the chemical outlet nozzle will be Open the chemical compartment on the front of the equipment folding the door forward Chemical connect...

Страница 22: ...ruding from the machine against the nozzle of the packaging outlet until you hear the CLICK that means the connection has been properly made Once the chemical outlet is connected close the compartment...

Страница 23: ...e is not going to be used for a while After performing this step the low pressure rins ing function will be deselected Once the stopcock for the mains water supply tap is closed select the manual rins...

Страница 24: ...st splashes and the inhalation of the vapours released by the chemical Before starting cleaning it is very important to read the label on the bag in box to find out about the properties and uses of CO...

Страница 25: ...age It must also be placed in its normal working position vertical and the brakes on the wheels applied It is not advisable to place the machine on a pallet or similar The machine must be on a complet...

Страница 26: ...clean dry and in good condition Lubricate the connector fittings at least once a month Remove the Bag in Box from the equipment for transport and if it is not going to be used Keep the grey bag in bo...

Страница 27: ...and care TEINNOVA stocks spare parts for all the machine s components as well as consumables for all the maintenance tasks shown in this manual If you need any part or consumable please contact TEINNO...

Страница 28: ...al collection points for recycling Do not dispose of electrical equipment in the trash We recommend that electrical tools and accessories are subjected to an environmentally friendly recovery process...

Страница 29: ...ctricity supply Check the mains voltage Malfunction in the electrical components of the equipment Contact Teinnova technical service Water intake pressure too low Check that the mains water inlet indi...

Страница 30: ...reen Empty weight Structural material Control panel Sound level Foaming power Rinsing power 340W 1 5A 12A 2640W 3A 18A 2040W less than 70 dB Length of the hose Pump pressure 67 kg 147 lb L x W x H 575...

Страница 31: ...ustomer s facilities and return of the product will be borne by the customer TEINNOVA reserves the right to overrule the application of the guarantee when there is no evidence of the product s non con...

Страница 32: ...ty certifies that the machine model described above complies with all the essential requirements of the following directives Machinery directive 2006 42 CE Directive 2014 30 EU on electromagnetic comp...

Отзывы: