10 TEGAM WAY • GENEVA, OHIO 44041 • 440-466-6100 • FAX 440-466-6110 • [email protected] 

37 

 

SERVICE INFORMATION 

 

 Warranty 

 

TEGAM, Inc. warrants this product to be free from defects in material and workmanship for a 

period of three years from the date of shipment. During this warranty period, if a product proves 

to be defective, TEGAM Inc., at its option, will either repair the defective product without charge 

for parts and labor or exchange any product that proves to be defective. 

 

TEGAM, Inc. warrants the calibration of this product for a period of two years from date of 

shipment. During this period, TEGAM, Inc. will recalibrate any product, which does not conform to 

the published accuracy specifications. 

 

In order to exercise this warranty, TEGAM, Inc., must be notified of the defective product before 

the expiration of the warranty period. The customer shall be responsible for packaging and 

shipping the product to the designated TEGAM service center with shipping charges prepaid. 

TEGAM Inc. shall pay for the return of the product to the customer if the shipment is to a location 

within the country in which the TEGAM service center is located. The customer shall be 

responsible for paying all shipping, duties, taxes, and additional costs if the product is 

transported to any other locations. Repaired products are warranted for the remaining balance of 

the original warranty, or 90 days, whichever period is longer. 

 

Warranty Limitations 

 

The TEGAM, Inc. warranty does not apply to defects resulting from unauthorized modification or 

misuse of the product or any part. This warranty does not apply to fuses, batteries, or damage to 

the instrument caused by battery leakage. 

 

This warranty is in lieu of all other warranties, expressed or implied, including any implied 

warranty of merchantability or fitness for a particular use. TEGAM, Inc. shall not be liable for any 

indirect, special or consequential damages. 

 

Statement of Calibration 

 

This instrument has been inspected and tested in accordance with specifications published by 

TEGAM Inc. The accuracy and calibration of this instrument are traceable to the National Institute 

of Standards and Technology through equipment, which is calibrated at planned intervals by 

comparison to certified standards maintained in the laboratories of TEGAM Inc. 

 

Contact Information: 

TEGAM INC. 

10 TEGAM WAY 

GENEVA, OHIO 44041 

PH: 440.466.6100 

FX: 440.466.6110 

EMAIL: 

[email protected] 

WEB: 

http://www.tegam.com 

 

 

 

 

 

 

 

 

Содержание 840A

Страница 1: ...840A 845 850 855 This owner s manual was as current as possible when this product was manufactured However products are constantly being updated and improved Because of this some differences may occu...

Страница 2: ...eter Mode Operation RTD Thermistor Ohms 12 5 Data Logging Recall 14 6 Calibrator Mode Operation Thermocouples 16 7 Calibrator Mode Operation RTD Thermistor Ohms 17 8 Storage and Recall of Calibrator S...

Страница 3: ...OUTPUTS THERMOCOUPLE Miniature TC jack RTD OHMS THERMISTOR T series instrumentation connector THERMOCOUPLE TYPES K J T E N B R S G C D RTD TYPES 100 platinum 0 00385 1000 platinum 0 00385 THERMISTOR...

Страница 4: ...9999 9 200 A 99999 50 A THERMISTOR T 113 F 50 A T 113 F 2mA CALIBRATOR MODE OUTPUT LOAD THERMOCOUPLES 500 min CALIBRATOR MODE EXCITATION CURRENTS 100 RTD 0 5 1mA 0 1 2mA typ 1000 RTD 50 100 A 10 200...

Страница 5: ...BAT Low Battery OPEN Open Input Thermocouple RTD or Thermistor E 1 momentary Invalid Keypad Entry E 2 momentary Ramp Function Not Installed HI Temperature Reading or Keypad Entry Exceeds Rating LO Tem...

Страница 6: ...E N B R S G C D Thermocouples ACCURACY 18 C to 28 C ambient 2 years K J T E N 0 5 F rdg 50 F 1 0 F rdg 50 F B R S G C D 1 7 F TEMPERATURE COEFFICIENT From 0 C to 18 C and 28 C to 50 C K J T E N 0 002...

Страница 7: ...LCD includes annunciators for operating modes Up to 11 thermocouple types 2 RTD types and thermistor 1 or 0 1 resolution over temperature range of each sensor F and C scales Reading hold mode 10 memo...

Страница 8: ...dangers that could result in personal injury or death The CAUTION used in this manual explains hazards that could damage the instrument SAFETY PRECAUTIONS WARNING These instruments are intended for us...

Страница 9: ...oving the cover WARNING Never use this instrument or any probe or sensor inside a microwave oven CAUTION Avoid making sharp bends in probe or sensor lead wires Bending lead wires at a sharp angle can...

Страница 10: ...ttery compartment by sliding it off in the direction of the arrow located on the battery cover 2 Remove the old battery 3 Place the new battery in the battery compartment Be sure to observe proper pol...

Страница 11: ...Ni Cd battery and published specifications do not apply to measurements made during recharging Turn off the instrument to recharge the battery Allow 7 hours to recharge the battery fully Then unplug t...

Страница 12: ...uctions Display reads E2 momentarily 1 Attempt made to activate non installed ramp function NOTE RAMP Function enabled on Models 845 and 855 only Display reads HI 1 Meter mode input temperature exceed...

Страница 13: ...ent operation It also defaults to K type thermocouples and F readings with 0 1 resolution The corresponding LCD annunciators are enabled METER Unit functioning as a thermometer K K type thermocouple F...

Страница 14: ...display when first selected Both T and R annunciators remain on to indicate a Tungsten Rhenium selection To recall the actual G C D selection turn the unit off then on again for another momentary read...

Страница 15: ...odes is automatic 2 Set instrument to METER mode 3 Use the Sensor Select key to set the instrument to the appropriate function and range NOTE Due to limited display area 100 and 1000 RTD s are indicat...

Страница 16: ...he memory location numbers keys 0 1 9 The corresponding memory annunciator turns on and the meter returns momentarily to the OPR mode displaying thermocouple temperature eg STORE 7 NOTES The enabled l...

Страница 17: ...mode depress OPR after recalling the last reading All active location annunciators will turn on again together with the OPR annunciator NOTE Recalling data from unused i e empty locations will give a...

Страница 18: ...readout 5 Select the desired temperature scale F C key 6 Select the resolution desired 0 0 1 key NOTE With 1 resolution one less key stroke will be required to enter calibrator output temperatures via...

Страница 19: ...ransmitters operate with a pulsating current which won t work with the 850 855 These devices are normally provided with a calibration mode which when enabled stops sending pulsating current and suppli...

Страница 20: ...ator outputs observe specified limits to excitation currents If in doubt check current levels with a DMM in series with either source lead 1 or 3 NOTE Due to limited display area 100 and 1000 RTD s ar...

Страница 21: ...p is stored in a location already in use the new set up replaces the old Saved set ups are retained during power off To store a reading of 0 just press the CLEAR while in the CALIB OPR mode Then depre...

Страница 22: ...is feature allows the calibrator to automatically ramp up and down a user defined staircase Up and down keys allow for manual ramping by the user To activate the RAMP function the instrument must firs...

Страница 23: ...t procedure Products with thermocouple functions only follow the Thermocouple Calibration procedure below Products with resistance functions RTD thermistor ohms follow first the Thermocouple Calibrati...

Страница 24: ...n on U U T and verify that RTD and annunciators are flashing on the display This verifies removal of J1 and J2 respectively NOTE Flashing RTD indicates that zero offset corrections can be stored in EE...

Страница 25: ...e TC simulator output to Type T 32 F ALLOY mode 10 Reconfigure calibration set up per Figure 12 Allow 2 3 minutes for thermal stabilization 11 Calculate E1 as follows E1 U U T Reading 32 0 12 Set U U...

Страница 26: ...000mV P1 32 0 0 5 F 10 S 0 000mV P1 32 0 0 5 F 11 G 2 238mV P1 600 0 0 2 F 12 C 0 000mV P1 32 0 0 2 F 13 D 0 000mV P1 32 0 0 2 F exclusive of noise Table 2 Calibrator Mode Zero Gain Adjustments STEP...

Страница 27: ...Y GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 sales tegam com 25 SERVICE INFORMATION Figure 11 Calibration Setup Copper Mode Figure 12 Calibration Setup Meter Mode Figure 13 Calibration Setup Cali...

Страница 28: ...d at an ambient temperature of 23 C 1 C with relative humidity less than 80 Preparation for Calibration 1 Turn off unit and remove bottom cover Refer to Disassembly Instructions 2 Secure battery with...

Страница 29: ...10 TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 sales tegam com 27 SERVICE INFORMATION Figure 14 Resistance Calibration Setup...

Страница 30: ...5 Switch current source to OPERATE mode 6 Perform calibrator mode adjustments and verifications per Table 4 use Table 6 for RTD Thermistor models 7 Turn off unit Remove tape holding battery 8 Re insta...

Страница 31: ...2 0 F 100 A 0 10000 0 00003V 6 1 000 900 00 1mA 0 90000 0 00010V 7 1 000 1 00 1mA 0 00100 0 00010V 8 10 000 9000 0 100 A 0 900000 0 00010V 9 10 000 10 0 100 A 0 000100 0 00010V exclusive of noise Tabl...

Страница 32: ...40 0 F 10 A 0 75790 0 00500V exclusive of noise 2 CALIBRATION VERIFICATION Calibration is verified with the same instrument hookups as used for calibration ie Figures 12 and 13 for thermocouple funct...

Страница 33: ...e s from the ITS 90 table This feature enables the user to make accurate temperature measurements without making manual calculations for error corrections COPPER MODE VERIFICATION PROCEDURE FOR THERMO...

Страница 34: ...2500 0 F display will blink and NUM will appear on the display 17 Press 3 2 0 buttons and then press the ENTER function button NUM will disappear and 32 0 F will appear not blinking The voltmeter shou...

Страница 35: ...blinking The voltmeter should read 2 238 mV 32 Press the SENSOR SELECT function button The sensor type will change to type C A C will appear momentarily in the center of the display 600 0 will then ap...

Страница 36: ...simulator voltage source 3 Voltmeter accurate to 1 uV resolution 4 Cable assembly 1 Start your calibration with a fresh battery 2 Press the ON function button to turn the unit on 3 Select the calibra...

Страница 37: ...TER function button on the U U T and ensure the U U T is still set for F and type K thermocouple 13 Set the thermocouple simulator to type K and output an output of 32 0 F The U U T should read 32 0 F...

Страница 38: ...10 TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 sales tegam com 36 SERVICE INFORMATION 3 MECHANICAL PARTS DIAGRAM...

Страница 39: ...service center is located The customer shall be responsible for paying all shipping duties taxes and additional costs if the product is transported to any other locations Repaired products are warrant...

Страница 40: ...and working standards and testing apparatus in accordance with established procedures and documented results Reference ANSI NCSL Z540 1 1994 Final calibration of this instrument was performed with re...

Отзывы: