Remove the appliance from its packaging and
read the instructions carefully before using the
appliance for the first time.
Install the appliance on a fl at dry surface
that is not hot. Remove all the packaging,
stickers or different accessories inside and
outside the appliance.
To open the appliance, turn the
open/ close handle on top of the lid,
until the marking is in line with the
open padlock.
CLEAN THE DIFFERENT COMPONENTS
1
Cooking bowl
2
Metal plate with non-removeable seal
3
Valve cover
4
Condensation collector
5
Steam basket
6
Decompression ball
HOW TO
DISMANTLE
AND REASSEMBLE
THE METAL PLATE
HOW TO REMOVE THE METAL
PLATE:
Grip the metal plate holding it by the seal, and
unscrew the central nut in an anti-clockwise
direction. Remove the nut and keep it in a safe
place. Press the spring loaded screw spindle to
release the metal plate. Remove the metal plate.
PUTTING THE METAL PLATE BACK
IN PLACE:
Grip the metal plate by the seal as shown
in the picture. Line up the metal plate with the
central screw spindle and press it fl at against
the underside of the lid. Put the nut back on
with the fl at side facing the metal plate and
turn it clockwise, tightening it as far as it will go.
HOW TO TAKE THE VALVE COVER OFF:
Hold the valve cover by its middle part (as shown) ;
Then turn it slightly to unclip it.
Clean the valve cover, paying special attention to the inside
(check that there is no left over food).
PUTTING THE VALVE COVER BACK:
Take the valve cover as shown in the picture
(gripping the middle).
Line up the interior circular shape with the three
hooks and then push so that the valve cover clips
on (you should hear a “click” sound).
The valve cover must be close up against
the inside of the lid.
ACCESSING THE DECOMPRESSION BALL:
When the lid is completely cool, turn the ball cover, anti-clockwise, so as to
bring the
I
marker into position
. Lift off the cover. Remove the ball, and
gently clean it, along with its cover, with water and some washing-up liquid.
Dry the ball using a soft cloth, then put it back in position. Put the ball cover
back in place, and the marker
I
in position
. Lock it by turning the ball
cover so that the marker is opposite the pictogram “closed”
.
Note: The metal decompression ball may
still be hot even when the lid has cooled
The notches on the rotating inner part of the lid must be correctly aligned with
the notches on the rim of the bowl otherwise the lid will not lock when closed.
3
4
5
Safety
valve
Manometric
rod
1
2
1
2
3
4
5
6
11
BEFORE USE
BEFORE USE
TEFAL-Notice_COOK4ME_EN.indd 10-11
TEFAL-Notice_COOK4ME_EN.indd 10-11
10/03/14 12:11
10/03/14 12:11