16
98-05334-EN R2
DynaJet
®
Flex
55295 E-CHEMSAVER® MAINTENANCE INSTRUCTIONS
The 55295 e-ChemSaver is a solenoid-actuated shutoff compatible with a wide range of TeeJet nozzle bodies equipped with a diaphragm
check valve. It can be used for end-of-boom nozzles as well as individual nozzle shutoff and PWM controls.
The valve is normally closed and opens when the solenoid is energized. The 55295 has a 2-pin MetriPack connector molded into the body for
a clean, weather-tight electrical connection.
General disassembly and reassembly
Note: O-rings (8, 9, 10) should be handled with care as they can be damaged/deformed
1.
Loosen and remove the nylon nut (4) and stainless steel washer (5)
2.
Separate the coil assembly (1) from the rest of the tube/plunger assembly (2, 3, 6-11)
3. Remove the locking ring (11)
4.
Using pliers to grip the stainless steel interface cap (7), loosen the tube sub-assembly (2) using a 14 mm or adjustable wrench. Note a
low-profile 14 mm wrench is available from TeeJet using part number 97-00067.
All repairable parts should be accessible
at this point. The plunger sub-assembly
(3), stainless steel spring (6), and O-rings
(8, 9, 10) can be replaced without further
disassembly
5.
During reassembly, place the plunger
sub-assembly (3) and stainless steel
spring (6) in the tube sub-assembly (2)
NOTE: the plunger sub-assembly
(3) should be oriented with the black
insert facing outward (visible) when
placed in the tube sub-assembly (2)
6. While compressing the spring (6), thread
the tube/plunger assembly (2, 3, 6-11) to
the stainless steel interface cap (7) and
tighten using a wrench and pliers
Optional: apply 1 drop of
Loctite Blue 243 to the threads of
the interface cap (7) and tube sub-
assembly (2)
Torque specifications: tighten
interface cap (7) and tube sub-
assembly (2) to 12 in-lbs (1.36 N-m)
7. Return the locking ring (11) to its original
position and slide the tube/plunger
assembly (2, 3, 6-11) through the coil
assembly (1)
NOTE: the coil assembly (1) should
be oriented with the MetriPack
connectors facing away from the
interface cap (7)
8.
Place the stainless steel washer (5)
above the coil assembly (1) and tighten
the nylon nut (4) to the tube/plunger
assembly (2, 3, 6-11)
Содержание DynaJet Flex 7120
Страница 23: ......