DynaJet
®
Flex
Units
Sets the units to us (PSI) or metric (bar)
Figure 8: Units
Number of sections
Set the number of boom sections. This should match the number of
sections used on the spray controller. Range is 1 to 15.
Figure 9: Number of sections
Maximum pressure sensor value
Verify this value by looking at the pressure sensor description.
Values will be either 10 bar or 25 bar.
If pressure value displayed on the DynaJet Flex console are not
accurate compared to a mechanical gauge, adjust this value until
there is a match.
►Increasing the value will reduce the pressure value displayed
during operation
►Decreasing this value will increase the pressure value
displayed during operation
Figure 10: Maximum pressure sensor value
Nozzle selection
Accesses the nozzle selection process to select which nozzle
is to be used. At this time only TeeJet nozzles are supported.
Figure 11: Nozzle selection
Select nozzle series
Use the green up and down arrows to highlight the correct spray
nozzle series/family.
Figure 12: Select nozzle series
Select nozzle capacity
With the correct nozzle capacity highlighted, select the
HOME icon
to return to operating mode. The selected nozzle will
be active and will automatically be added to the favorites list.
Figure 13: Select nozzle capacity