6.2   Drilling holes for piping, condensed water hose and power cable.

a. 

 Determine the position of the hole according the diagram in Fig. 9. Drill a hole with a diameter 

 65 

mm, directed slightly down in the direction of the outdoor unit; this will prevent water seeping inside 
(Fig. 10).

b.  

 Always use a drilling gauge for drilling in metal gratings, metal sheets or similar materials.

Wall

Inside

Outside

Figure 10

5 - 7 mm 

per 100 mm

7.  CONNECTING THE REFRIGERANT PIPING
  
 

7.1   Connecting the refrigerant piping

a. 

 Provide the pipe ends with a flare with swivel or similar screw connection.

b.  

 Inner part: Secure the swivel nut manually to the piping of the indoor unit and secure the swivel nut 
with an open-end wrench and a torque wrench as shown in Fig. 13.

c.  

 Outer part: Secure the swivel nut manually to the fittings on the valves of the outdoor unit and 
secure the swivel nut with an open-end wrench and a torque wrench as shown in Fig. 13.

Piping from 

indoor unit

Swivel nut

Piping

Figure 13

d.  

 Apply the correct torques (see table 1) to prevent damaging the piping, fittings and nuts.

Outside- 

diameter

Torque 

(N.cm)

Extra torque  

(N.cm)

Ø 6.35

1500

(153kgf.cm)

1600

(163kgf.cm)

Ø 9.53

2500

(255kgf.cm)

2600

(265kgf.cm)

Ø 12.7

3500

(357kgf.cm).

3600

(367kgf.cm)

Ø 16.0

4500

(459kgf.cm)

4700

(479kgf.cm)

e.  

 Insulate the fittings on the indoor unit with insulation to prevent condensed water leakage.

6.   MOUNTING THE INSTALLATION PLATE AND DRILLING HOLES FOR PIPING.
  
 

6.1 Mounting the installation plate of the indoor unit.

WARNING

Use a detector before drilling the holes in the wall to detect power cables and piping in the wall 
to avoid unnecessary damaging the wall and to avoid dangerous situations. 

note

a.  

 Position the installation plate 

 level and on a sufficiently firm wall and leave a free space around 

the installation plate. See Figure 8.

b.  

  If the wall is made of bricks, concrete or a similar material, eight holes with a diameter of 5 mm have 
to be drilled in the wall. Insert the plugs 

 for the respective mounting screws 

 in the wall.

c.  

Mount the installation plate 

 on the wall with eight type “A” screws 

.

G

NOTE

Mount the installation plate and drill wholes in the wall according the material in which the wall 
is build and the respective attachment points on the installation plate. (dimensions are in “mm” 
unless indicated otherwise).

Correct mounting of 

the installation plate

Figure 8

4

42

Содержание 8713508778433

Страница 1: ...MULTI Installation Manual 2 18 34 50 66 82 98 MANUAL DE INSTALACI N MANUEL D INSTALLATION INSTALLATION MANUAL MANUALE DI INSTALLAZIONE INSTALLATIEHANDLEIDING MANUAL DE INSTALA O PRIRO NIK ZA NAMESTIT...

Страница 2: ...eriencia con aparatos el ctri cos electr nicos instalaciones de tecnolog as de refrigeraci n y mec nicas Intentar instalar o reparar este aparato puede provocar lesiones y da os materiales Ni el fabri...

Страница 3: ...o un t cnico autorizado G ADVERTENCIA No compruebe usted mismo el aire acondicionado La instalaci n incorrecta puede provocar incendio descarga el ctrica ca da del aparato o filtraciones de agua que p...

Страница 4: ...directos Seleccione un lugar sin obst culos delante o alrededor de la unidad Aseg rese de que el agua condensada se desagua a un punto inferior en todo momento No coloque la unidad cerca de una puert...

Страница 5: ...sulte la Figura 7 La tuber a puede conectarse con un enchufe a la parte trasera derecha o izquierda Consulte la Figura 7 Figura 7 G ATENCI N La longitud m xima de la tuber a entre la unidad interior y...

Страница 6: ...como se muestra en la Fig 13 Tuber a de unidad interior Tuerca giratoria Tuber a Figura 13 d Utilice los pares correctos consulte la tabla 1 para evitar da os en la tuber a las conexiones y las tuerca...

Страница 7: ...or t cnicos cualificados Di metro exterior Par N cm Par adicional N cm 6 35 1500 153 kgf cm 1600 163 kgf cm 9 53 2500 255 kgf cm 2600 265 kgf cm 12 7 3500 357 kgf cm 3600 367 kgf cm 16 0 4500 459 kgf...

Страница 8: ...unit 1 Indoor unit 2 Open this cover see the wiring terminal of out door unit as following figure on the electrical box Open this inlet air griller see the wiring terminal of indoor unit as following...

Страница 9: ...un aire acondicionado debe hacerse de acuerdo con las disposiciones legales vigentes La evacuaci n de la tuber a de refrigerante y la unidad interior solo puede llevarse a cabo por un instalador cert...

Страница 10: ...ricit lectronique m canique et techniques du froid Tenter d installer ou de r parer soi m me l appareil est dangereux et peut entra ner des blessures ou endommager le mat riel Le fabricant ou le vende...

Страница 11: ...agr une fois par an G AVERTISSEMENT Ne pas installer cet quipement soi m me L installation incorrecte de l appareil peut provoquer des blessures par incendie choc lectrique chute de l appareil ou fui...

Страница 12: ...gag tant l avant qu l arri re et sur les c t s S assurer que la condensation est constamment drain e vers le bas Ne pas installer l unit proximit d une porte S assurer que le d gagement gauche et dro...

Страница 13: ...ce faire tez la plaque frangible droite ou gauche Cf Illustration 7 Le raccordement des tuyaux l arri re peut tre r alis gauche ou droite Cf Illustration 7 Fig 7 G ATTENTION La longueur de tuyau maxim...

Страница 14: ...tion 13 Conduit unit int rieure crou vas Tuyaux Fig 13 d S lectionner le couple correct illustr au tableau 1 afin d viter que les tuyaux les raccords et les crous ne se d t riorent 6 MONTAGE DE LA PLA...

Страница 15: ...vacuation de l eau de condensation sous les tuyaux de refroidissement afin d viter que le bac de r ception d eau puisse d border 3 28 MISE EN GARDE S assurer que le flexible de drainage est situ en ba...

Страница 16: ...de raccordement entre console et compresseur doit tre raccord e sur le bloc de jonction B Sur le groupe de robinets du compresseur les lettres A et B correspondent g Branchez les c bles de liaison sur...

Страница 17: ...limatiseur M thode de l eau savonneuse Appliquer de l eau savonneuse ou un d tergent liquide neutre sur les raccords des unit s int rieure et ext rieure l aide d un pinceau souple afin de d tecter tou...

Страница 18: ...onics cooling technology and mechanical installations Attempting to install or repair the device can cause injuries and damaged properties The manufacturer neither the vendor is responsible for the in...

Страница 19: ...y an authorised technician G WARNING Don t test the air conditioning yourself Improper installation can cause fire electric shocks falling over of the device or water leakage which can lead to injury...

Страница 20: ...ont or around the unit Make sure the condensed water can be drained to a lower point at all times Don t position the unit near a door Make sure that there is at least 12 cm free space to the left and...

Страница 21: ...ft or right rupture disc as necessary See Figure 7 The piping can be connected with an outlet to the right rear or rear left See Figure 7 Figure 7 G ATTENTION The maximum length of the piping between...

Страница 22: ...s Outside diameter Torque N cm Extra torque N cm 6 35 1500 153kgf cm 1600 163kgf cm 9 53 2500 255kgf cm 2600 265kgf cm 12 7 3500 357kgf cm 3600 367kgf cm 16 0 4500 459kgf cm 4700 479kgf cm e Insulate...

Страница 23: ...ee chapter 11 All wiring has to comply with national and local electrical standards and regulations and has to be connected by qualified technicians f Wrap the piping connecting cable and outlet hose...

Страница 24: ...nit 1 Indoor unit 2 Open this cover see the wiring terminal of out door unit as following figure on the electrical box Open this inlet air griller see the wiring terminal of indoor unit as following f...

Страница 25: ...statutory provisions Vacuuming of the refrigerant piping and the indoor unit may only be performed by a certified air conditioner technician 12 CHECKING THE LEAK TIGHTNESS OF THE COOLING SYSTEM G ATTE...

Страница 26: ...ronica delle tecniche di refrigerazione e delle installazioni meccaniche Qualsiasi tentativo di installare o di riparare un dispositivo pu provocare lesioni fisiche e danni al materiale Il fabbricante...

Страница 27: ...o e va effettuata la manutenzione una volta l anno da parte di un montatore di sistemi di condizionamento competente G AVVERTENZA Non installare il condizionatore per conto proprio Un installazione sc...

Страница 28: ...enti ostacoli davanti o attorno all unit Assicurarsi che l acqua di condensa possa essere scaricata continuamente verso il basso Non posizionare l unit nei dintorni di porte che si aprono Assicurarsi...

Страница 29: ...resistente Se non cos deve essere rinforzata I collegamenti tra sostegno e parete e tra sostegno e condizionatore devono essere resistenti stabili e duraturi In caso di dubbi o incertezze a proposito...

Страница 30: ...dutture possono essere allacciate con un estremit sul lato sinistro o destro dell unit interna A tale scopo rimuovere il disco di rottura sinistro o destro Le condutture si possono allacciare con un e...

Страница 31: ...ENTO DELLE CONDUTTURE DEL REFRIGERATORE 7 1 Allacciamento delle condutture del refrigeratore a Dotare le estremit delle condutture di un cosiddetto cono con raccordo o di una connessione a vite simile...

Страница 32: ...li con capacit 4 5 kW connettere il cavo di alimentazione direttamente alla fonte di corrente Non usare una spina con una presa a causa della corrente elevata i poli sia della spina che della presa po...

Страница 33: ...sulla placca del modello 14 GIRO DI PROVA DOPO L INSTALLAZIONE Effettuare un giro di prova del dispositivo quando stato stabilito che l installazione di elettricit e gas sicura Il giro di prova deve d...

Страница 34: ...paraat te installeren of te repareren kunnen leiden tot lichamelijk letsel en materi le schade De fabri kant of verkoper is niet verantwoordelijk voor de interpretatie van deze informatie en is niet a...

Страница 35: ...een bevoegde aircomonteur G WAARSCHUWING Installeer de airconditioning niet zelf Onjuiste installatie kan tot brand elektrische schokken het vallen van het apparaat of waterlekkage leiden en daardoor...

Страница 36: ...nu omlaag kan worden afgevoerd Plaats de unit niet in de buurt van een deuropening Zorg ervoor dat de ruimte links en rechts van de unit meer dan 12 cm bedraagt Zie afbeelding 4 Gebruik een leidingzoe...

Страница 37: ...g 7 De leidingen kunnen worden aangesloten met een uitloop naar de rechterachterzijde of de linker achterzijde Zie afbeelding 7 Afbeelding 7 G LET OP De maximale leidinglengte tussen binnen en buitend...

Страница 38: ...Leiding van binnenunit Wartelmoer Leidingen Afbeelding 13 d Pas de juiste aanhaalmomenten toe zie tabel 1 om te voorkomen dat de leidingen verbindingsstuk ken en moeren beschadigd raken 6 MONTAGE VAN...

Страница 39: ...sen worden aangesloten Buiten diameter Aanhaalmoment N cm Extra aanhaalmoment N cm 6 35 1500 153kgf cm 1600 163kgf cm 9 53 2500 255kgf cm 2600 265kgf cm 12 7 3500 357kgf cm 3600 367kgf cm 16 0 4500 45...

Страница 40: ...SYSTEM B SYSTEM B SYSTEM A SYSTEM Indoor unit 1 Indoor unit 2 Open this cover see the wiring terminal of out door unit as following figure on the electrical box Open this inlet air griller see the wi...

Страница 41: ...bepalingen Het vacumeren van de koudemiddelleidingen en het binnendeel mag alleen worden uitgevoerd door een gecertificeerd airconditioner monteur 12 CONTROLE OP LEKDICHTHEID VAN HET KOUDEMIDDELSYSTE...

Страница 42: ...tricos sistemas eletr nicos tecnologia de refrigera o e instala es mec nicas A tentativa de instala o ou repara o do dispositivo pode causar les es e danos de propriedade Nem o fabricante nem o fornec...

Страница 43: ...t cnico autorizado G ADVERT NCIA N o teste o ar condicionado voc mesmo Uma instala o inadequada pode provocar inc ndio choques el tricos queda do dispositivo ou fugas de gua o que pode resultar em les...

Страница 44: ...ao vapor Escolha um lugar sem obst culos frente ou volta da unidade Certifique se de que a gua condensada pode ser drenada sempre para um ponto inferior N o coloque a unidade perto de uma porta Certif...

Страница 45: ...co de rutura esquerdo ou direito conforme necess rio Consulte a Figura 7 A tubagem pode ser ligada a uma sa da na parte traseira direita ou traseira esquerda Consulte a Figura 7 Figura 7 G ATEN O O co...

Страница 46: ...ca como mostrado na Fig 13 Tubagem da unidade interior Porca articulada Tubagem Figura 13 d Aplique os bin rios corretos consulte a tabela 1 para evitar danificar a tubagem encaixes e porcas 6 MONTAGE...

Страница 47: ...ados Di metro exter no Bin rio N cm Bin rio extra N cm 6 35 1500 153 kgf cm 1600 163 kgf cm 9 53 2500 255 kgf cm 2600 265 kgf cm 12 7 3500 357 kgf cm 3600 367 kgf cm 16 0 4500 459 kgf cm 4700 479 kgf...

Страница 48: ...nit 2 Open this cover see the wiring terminal of out door unit as following figure on the electrical box Open this inlet air griller see the wiring terminal of indoor unit as following figure on the e...

Страница 49: ...ra o da tubagem de fluido refrigerante e da unidade interior s pode ser efetuada por um t cnico de ar condicionado certificado 12 VERIFICA O DA ESTANQUEIDADE DO SISTEMA DE REFRIGERA O G ATEN O A verif...

Страница 50: ...lektri nimi napravami elektroniko hladilno tehnologijo in mehani nimi in talacijami Poskus namestitve ali popravila naprave lahko povzro i telesne po kodbe in materialno kodo Proizvajalec in prodajale...

Страница 51: ...en tehnik Klimatsko napravo mora vsakoletno pre gledati in servisirati poobla eni tehnik G OPOZORILO Klimatske enote ne preizku ajte sami Nepravilna namestitev lahko povzro i po ar elektri ne udare pa...

Страница 52: ...toploti ali pari Izberite prostor kjer pred enoto oziroma okoli nje ne bo ovir Poskrbite da bo lahko kondenzirana voda vedno odtekla na ni jo to ko Enote ne namestite v bli ini vrat Poskrbite da bo l...

Страница 53: ...odstranite levo ali desno prelomno plo o Glejte sliko 7 Cevje lahko pove ete z izhodom na desni zadaj ali levo zadaj Glejte sliko 7 Slika 7 G POZOR Najdalj a dol ina cevi med notranjo in zunanjo enoto...

Страница 54: ...a prepre ite po kodbe cevi napeljave in matic Zunanji premer Navor N cm Dodatni navor N cm 6 35 1500 153 kgf cm 1600 163 kgf cm 9 53 2500 255 kgf cm 2600 265 kgf cm 12 7 3500 357 kgf cm 3600 367 kgf c...

Страница 55: ...abel in odvajalno cev ki so za notranjo enoto ovijte s trakom tako da bo nastal trden omot S tem bo namestitev notranje enote na namestitveno plo o la je Notranja enota Cevje Ovijalni trak Povezovalni...

Страница 56: ...to mora biti kabel tipa H07RN F 2 5 mm c Za povezavo kabla z blokom priklju nih sponk notranje enote Odstranite sprednjo plo o in pokrov bloka priklju nih sponk Blok priklju nih sponk je na desni stra...

Страница 57: ...nalnimi statutornimi ukrepi Sesanje cevi za hladilno teko ino in notranje enote lahko izvede samo certificirani tehnik za klimatske naprave 12 PREVERJANJE TESNJENJA HLADILNEGA SISTEMA G POZOR Preverja...

Страница 58: ...115 114 115 114...

Страница 59: ...eu oppure contattate il Centro Assistenza Clienti per conoscere il numero di telefono consultate www pvg eu N Hvis du trenger informasjon eller hvis du har et problem med produktet kan du g til nettsi...

Отзывы: