26
Group 06: Automatic Program Operation
Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
06-15
*Frequency
Setting of
Operation-
Stage 15
0.00~599.00 5.00
*1
06-16
Operation
Time Setting
of Speed-
Stage 0
0.0~6000.0 0.0
*1
06-17
Operation
Time Setting
of Speed-
Stage 1
0.0~6000.0 0.0
*1
06-18
Operation
Time Setting
of Speed-
Stage 2
0.0~6000.0 0.0
*1
06-19
Operation
Time Setting
of Speed-
Stage 3
0.0~6000.0 0.0
*1
06-20
Operation
Time Setting
of Speed-
Stage 4
0.0~6000.0 0.0
*1
06-21
Operation
Time Setting
of Speed-
Stage 5
0.0~6000.0 0.0
*1
06-22
Operation
Time Setting
of Speed-
Stage 6
0.0~6000.0 0.0
*1
06-23
Operation
Time Setting
of Speed-
Stage 7
0.0~6000.0 0.0
*1
06-24
Operation
Time Setting
of Speed-
Stage 8
0.0~6000.0 0.0
*1
06-25
Operation
Time Setting
of Speed-
Stage 9
0.0~6000.0 0.0
*1
06-26
Operation
Time Setting
of Speed-
Stage 10
0.0~6000.0 0.0
*1
06-27
Operation
Time Setting
of Speed-
Stage 11
0.0~6000.0 0.0
*1
06-28
Operation
Time Setting
of Speed-
Stage 12
0.0~6000.0 0.0
*1
06-29
Operation
Time Setting
0.0~6000.0 0.0
*1
Group 06: Automatic Program Operation
Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
of Speed-
Stage 13
06-30
Operation
Time Setting
of Speed-
Stage 14
0.0~6000.0 0.0
*1
06-31
Operation
Time Setting
of Speed-
Stage 15
0.0~6000.0 0.0
*1
06-32
Operation
Direction
Selection of
Speed-Stage 0
0: Stop
1: Forward
2: Reverse
0
06-33
Operation
Direction
Selection of
Speed-Stage 1
0: Stop
1: Forward
2: Reverse
0
06-34
Operation
Direction
Selection of
Speed-Stage 2
0: Stop
1: Forward
2: Reverse
0
06-35
Operation
Direction
Selection of
Speed-Stage 3
0: Stop
1: Forward
2: Reverse
0
06-36
Operation
Direction
Selection of
Speed-Stage 4
0: Stop
1: Forward
2: Reverse
0
06-37
Operation
Direction
Selection of
Speed-Stage 5
0: Stop
1: Forward
2: Reverse
0
06-38
Operation
Direction
Selection of
Speed-Stage 6
0: Stop
1: Forward
2: Reverse
0
06-39
Operation
Direction
Selection of
Speed-Stage 7
0: Stop
1: Forward
2: Reverse
0
06-40
Operation
Direction
Selection of
Speed-Stage 8
0: Stop
1: Forward
2: Reverse
0
06-41
Operation
Direction
Selection of
Speed-Stage 9
0: Stop
1: Forward
2: Reverse
0
06-42
Operation
Direction
Selection of
Speed-Stage
10
0: Stop
1: Forward
2: Reverse
0
06-43
Operation
Direction
Selection of
Speed-Stage
11
0: Stop
1: Forward
2: Reverse
0
06-44
Operation
Direction
Selection of
0: Stop
1: Forward
2: Reverse
0
Содержание A510s
Страница 1: ......
Страница 60: ...2 1 4 1 5 11 55 07 00 5 5 15Hp 15 1 6 25 14 104 140 F 10 40 60 C 95 RH...
Страница 61: ...3 2 2 1 NFB AC NFB NFB NFB 200mA 0 1 V TYPE AC AC EMC R S T E...
Страница 103: ...A 3 Type 1 During installation all conduit hole plugs shall be removed and all conduit holes shall be used 690V 80A...