6.11 PROHIBITED (SKIP) FREQUENCY
Cn-16 to -19
When an operation is required to avoid mechanical resonance frequency, the setting prohibited frequency
function is effective.
Setting prohibited frequency is set in Cn-16 to -18 in units of 0.1Hz.
Setting prohibited frequency width is set to Cn-19 in units of 0.1Hz.
Cn-18
Cn-17
Cn-19 Cn-19
Cn-16
Note: Ineffective when
set value is 0.0Hz.