7.5 MULTI-FUNCTION ANALOG INPUT SELECTION
Sn-19
(Cont’d)
Multi-function Analog Input Characteristics
(1) Sn-19 = 0
(2) Sn-19 = 1
(3) Sn-19 = 2
(4) Sn-19 = 3
(5) Sn-19 = 4
(6) Sn-19 = 5
(7) Sn-19 = 6
(8) Sn-19 = 7
Actual accel/decel time =
Accel/decel time (bn-01 to -04)
Reduction coefficient
(9) Sn-19 = 08
(10) Sn-19 = 09
(11) Sn-19 = 0A
MULTI-FUNCTION
ANALOG INPUT
0V
10V
1.00
MULTI-FUNCTION
ANALOG INPUT
0V
10V
5V
2.00
F GAIN
100%
FREQUENCY
REF.
0%
F BIAS 1
10%
MULTI-FUNCTION
ANALOG INPUT
0%
0V
10V
F BIAS 2
10%
MULTI-FUNCTION
ANALOG INPUT
0%
0V
10V
5V
-10%
OVER-
TORQUE
DETECTION
LEVEL
200%
MULTI-FUNCTION
ANALOG INPUT
0%
0V
10V
V BIAS
100V
MULTI-FUNCTION
ANALOG INPUT
0V
10V
DC
INJECTION
BRAKING
CURRENT
100%
MULTI-FUNCTION
ANALOG INPUT
0%
0V
10V
10
MULTI-FUNCTION
ANALOG INPUT
1
0V
10V
1V
REDUCTION
COEFFI-
CIENT
FREQUENCY
REFERENCE
LOWER LIMIT
(Cn-02)
MULTI-FUNCTION
ANALOG INPUT
0V
10V
MAX. OUTPUT FREQUENCY
200%
MULTI-FUNCTION
ANALOG INPUT
0V 1.5V
10V
STALL
LEVEL
DURING
RUNNING
30%
MAX. OUTPUT FREQUENCY
SETTING
PROHIBIT
FREQUENCY
(Cn-02)
MULTI-FUNCTION
ANALOG INPUT
0V
10V
─
96
─