35.
Only start the machine when the installation area is free of unauthorized personnel.
36.
The operator must not perform operations or interventions that are not his responsibility.
37.
The operator area must always be kept free and clean of any oil, liquid and solid residues as well as equipment that could be a hazard.
Attention
The electromagnet is a powerful magnetic field generator. It is absolutely forbidden for individuals with pacemakers or
artificial cardiac stimulators to be near it.
Intense magnetic field (EN12198)
5
USE OF THE HYDRAULIC MAGNET
5.3 OPERATION
5.3.4 ENVIRONMENAL CONDITIONS
ENVIRONMENTAL CHARACTERISTICS OF THE INSTALLATION AREA:
TEMPERATURE
FROM -10°C TO 50°
MAXIMUM MOISTURE
80%
ATTENTION
The hydraulic magnet must not be used in environments with corrosive and/or abrasive vapours, fumes or dust, in those with a risk of fire
or explosion and must not, in any case, be used in environments where the use of explosion-proof components is required.
ATTENTION
The hydraulic magnet must be used in a place with suitable lighting.
5
USE OF THE HYDRAULIC MAGNET
5.3 OPERATION
5.3.5 PERMITTED LOAD
The loads must consist of ferromagnetic material. When the materials to be moved are not mild steel, are alloyed and with a higher
carbon content, reductions must be made to the capacity of the system in accordance with the following table:
STEEL CASTING
0.9
SILICON STEEL (MIN. 3%)
0.8
HIGH CARBON OR ALLOYED STEEL
0.7
CAST IRON
0.45
ATTENTION
It is not permitted to lift loads exceeding the maximum defined in the technical data sheet in chapter 2.4.2.
If the magnet is connected to the operating machine through a rigid bracket, do not shake it to speed up load dumping. This may damage the
internal electronic control box.
Division: Tecnoter srl
Hyd. Magnet
LQMI
Ver. T
Page 26/38
Rev: 1.0a_En –
15/07/2018