OIL SEPARATING PROCEDURE
1.Make sure all connections are correct and tight.
2.Make sure the port of drain valve is closed.
3.Make sure the MODE valve on RECOVERY position.
4.Open the liquid port of the storage tank.
5.Open the output port of the unit and liquid port on the manifold gauge set.
6.Turn the power switch to ON. Open the input valve slowly to liquid position. Run until the recovery is achieved.
7. Turn the power switch to OFF. Open the port of oil drain valve, and drain the oil into a suitable container, then
close the oil drain port.
8. Disconnect all hoses.
TROUBLESHOOTING
PROBLEM
CAUSE
ACTION
Fan does not run when Power Switch is in
ON position
Power supply cord not attached voltage
is not right
The circuit breaker has cut off
Attach the power supply cord.
Check the power supply at job site.
Press the button to reset
Fan runs but compressor does not start
The recovery machine is in high pressure
shut off.
Output pressure is too high
Failure in motor, or in other electrical
components.
Reduce pressure and then press the button
of the High Pressure Switch.
Rotate INPUT valve and MODE valve to
PURGE, then rotate INPUT valve back to
OPEN, and MODE valve to RECOVER
Factory service required
Compressor starts but cuts off within a few
minutes
MODE valve is in PURGE position
Output valve is not open and high pressure
activates
Recovery tank valve is not open
Rotate MODEvalve to RECOVER
Rotate OUTPUT valve to OPEN
Open recovery tank valve
Recovery process too slow
Head pressure too high
Compressor seals are worn
Reduce tank temperature with
TANK COOLING PROCEDURE
Factory service required
Recovery machine does
not pull out a vacuum
Connecting hoses are loose
Leakage in unit
Tighten the connecting hoses
Factory service required