TECNORD
RC-DBX/PCM/NBM
Use and Maintenance Manual
Page
23/23
8.4.3
System Type Setup
This parameter specifies wether the system has or not a PWM output (i.e. it is an RC-DBD or RC-DBR system). It is configurable
with one of the following values:
Setting Value
displayed
DESCRIPTION
DBD
S_0
On-off system (EVR and EV9 are neither activated nor considered in diagnostics)
DBR
S_1
PWM system (EVR and EV9 outputs are activated, diagnostics on EVR is active)
8.4.4
EV9 Mode of Operation Setup
This parameter specifies wether the safety valve labeled EV9 depends on the Emergency Stop or on the Function activation. It is
configurable with one of the following values:
Setting Value
displayed
DESCRIPTION
LEVER
9_L
EV9 output is activated when at least one function is active
E-STOP
9_E
EV9 output is activated when the E-Stop is released and safe communication takes place
8.4.5
EV49 Mode of Operation Setup
This parameter specifies wether the safety valve labeled EV49 depends on the Emergency Stop or on the Function activation. It is
configurable with one of the following values:
Setting Value
displayed
DESCRIPTION
LEVER
49L
EV49 output is activated when at least one function is active
E-STOP
49E
EV49 output is activated when the E-Stop is released and safe communication takes place
8.4.6
Analog Voltage Output Range Setup
This parameter specifies which kind of system is driven by the analog voltage outputs of an RC-DBM , RC-PCM or RC-NBM system.
Its value affects the voltage values displayed during parameters adjustments and tells the system if the output voltage must be an
absolute value or ratiometric with respect to the measured battery voltage. It is configurable with one of the following values:
Setting Value
displayed
DESCRIPTION
ML4
U_0
MLT FD4 system. Reference values are 0,9V – 2,5V – 4,1V (absolute)
ML2
U_1
MLT L2 system. Reference values are 2V – 4V – 6V (absolute)
DNF12
U_2
12V DNF system. Reference values are 3V – 6V – 9V (ratiometric)
DNF24
U_3
24V DNF system. Reference values are 6V – 12V – 18V (ratiometric)
SMD
U_4
SMD system. Reference values are 2V – 4V – 6V (absolute)
WARNINGS (as required by FCC part 15 and IC RSS-210):
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) This device must accept any interference, including interference that may cause undesired operation.
This equipment has been approved for mobile applications where the equipment should be used at distances greater than 20cm
from the human body (with the exception of hands, wrists, feet and ankles). Operation at distances less than 20cm is strictly prohibited.
In any case the message coding and elaboration ensures that no outputs are activated due to radio interferences. Outputs are
activated only when the corresponding messages are received and interpreted as correct.