8.3
Calibration Menu
This paragraph is applicable only to systems that implement a proportional current output. The calibration of the parameters of the
proportional output is carried out using the two Pushbuttons (Blue Key and Yellow Key) integrated in the receiver’s electronics, shown in
the figure below.
DBX-RX RECEIVER WITH TWO PUSHBUTTONS
8.3.1
Calibration parameters for DBR systems
Instructions for the Calibration Procedure:
1.
Keep the Receiver’s electronics outside its enclosure in order to access the two pushbuttons: Blue Key (B-KEY) and Yellow Key (Y-
KEY).
2.
Press simultaneously the Blue and Yellow keys for at least three seconds, until the dot on the right digit turns on and the value of
the configured minimum current I
MIN
(in mA) is displayed. Release the keys in order to go on with the calibration procedure.
3.
The menu allows four calibrations, in order: minimum current, maximum current, acceleration time ramp, deceleration time ramp.
In order to switch from one calibration to the next, press simultaneously the Blue and Yellow keys.
In the calibration menu the display dots give information about which parameter is currently being configured in the following way:
Setup of the minimum current I
MIN
(in mA)
Example: “I
MIN
= 410 mA”.
Setup of the maximum current I
MAX
(in mA)
Example: “I
MAX
= 610 mA”.
Setup of the acceleration time ramp
(from 1 to 100 steps of 50ms each)
Example: “acceleration time ramp 500ms”.
(10 x 50ms = 500ms)
Setup of the deceleration time ramp
(from 1 to 100 steps of 50ms each)
Example: “deceleration time ramp 500ms”.
(10 x 50ms = 500ms)