Instruction and maintenance manual
ENGLISH
3.4.3 ST200 (model with 7 levels)
To.be.able.to.use.several.levels.of.magnetization,.it.is.
possible.to.replace.the.basic.push-button.panel.with.
a.7-level.model.that.enables.to.control.milling.and.
grinding.chucks.
This. push-button. panel. has. the. following. five. but-
tons:
•..Magnetization..
.
MAG,
•..Increase.of.magnetization.
. level... .
.
+
•..Reduction.of.magnetization.
. level.. .
.
–
.
•..Demagnetization.. .
DEMAG,
•..Enabling..
.
ENABLE.
The.
ENABLE
.button.is.used.together.with.the.mag-
netization.and.demagnetization.buttons,.depending.
on.the.cycle.that.needs.to.be.performed.
There.are.also.five.indicator.lights.placed.next.to.the.
full.
FULL-MAG,
.
DEMAG,
.
+
.and.
–
.buttons.and.the.
CYCLE
.and.
ALARM
.buttons.
These.indicator.lights.are.used.to.provide.informa-
tion.on.the.status.of.the.system,.which.is.automati-
cally.reset.to.the.last.operating.cycle.
Once. the. start. sequence. has. been. successfully.
completed,.the.indicator.light.corresponding.to.the.
total/partial. magnetization. or. demagnetization.
switches. on,. depending. on. the. option. selected.. A.
failure.in.the.start.sequence.switches.on.the.central.
alarm.indicator.light.
If.a.cycle.is.active,.the.only.LED.that.is.on.is.the.one.
related.to.the.cycle,.while.all.the.others.are.off.
The.
FULL-MAG
.and.
DEMAG
.indicator.lights.are.al-
ways.on.and.flash.during.partial.magnetization.cy-
cles.only.
J
G
I
H
D
E
F
A
C
B
PUSH-BUTTON PANEL
A
.
➜
MAG.button
B
.
➜
ENABLE.button
C
.
➜
DEMAG.button
D
.
➜
E
.
➜
Button.-
6
.
➜
FULL-MAG.Led.(fixed).of.MAG.Led.for.
.
. partial.magnetization.(flashing)
..
G
.
➜
Cycle.Led
H
.
➜
DEMAG.Led
I
.
➜
Alarm.status.Led.
J
.
➜
Level.selection.LED.(levels.from.1.to.7).and..
.
. FULL-MAG.8
System status
MAG Led
DEMAG Led
Cycle Led
Alarm Led
Full.magnetization
Level.8
Permanently.on
Off
Off
Off
Demag.
Off
Permanently.on
Off
Off
Partial.magnetization
Levels.1-7
On.flashing
Off
Off
Off
Cycle
Off
Off
Permanently.on
Off
Current.alarm
Off
Off
Off
Permanently.on
Communication.
alarm
*
Off
Off
Off
On.flashing
*
.For.version.ST200.only