Maintenance
GENERAL MAINTENANCE OF A SPRAYING DEVICE
99592 H
S D
To protect the machine's circuitry with an "antifreeze":
• Clean the sprayer thoroughly: use a cleaning product approved for your material.
• Rinse the device using clear water and operate until the tank is completely empty.
• Pour 50 litres of clear water and 20 litres of antifreeze into the rinse tank via the suction circuit.
• Transfer the mixture from the rinse tank into the main tank using the Lav'tons.
• Shake for a few minutes.
• Rinse the induction bowl by operating the suction circuit in a closed loop with the main tank. Remember to
activate the LAV'BOX and rinse hose or the rinse boom inside the hopper or use a rinse pistol.
• If your equipment is provided with on board options (i.e. pressure house + drum) spray through them for a
few minutes while rinsing the equipment and adding anti-freeze.
• If your boom is equipped with AGP, allow the liquid to circulate in the boom for a few minutes. Then spray
the liquid until the entire boom sprays the coloured liquid for a few seconds.
• If your boom is not equipped with AGP, spray the liquid until the entire boom sprays the coloured liquid for a
few seconds.
• you can recover the remaining product by draining the main tank.
• Do not empty, leave the device as it is.
• Before putting a piston-membrane pump back into operation at temperatures beneath 0° C,
loosen the pump by turning it by hand in order to avoid any ice particles damaging the pistons
and membranes.
• Keep the pressure gauge and all electronic accessories out of the cold!
Concentration
Protection Temperature
Centigrade
Fahrenheit
15 %
- 5°
23°
20 %
- 9°
15°
25 %
- 12°
10°
30 %
- 15°
5°
35 %
- 20°
- 4°
50 %
- 38°
- 36°
PAINT
If you must perform painting operations, do not fail to comply with the indications provided below
• Clean the casing completely using a high pressure cleaner.
→
Beware of water stagnation which may speed up rust formation.
• Cleaning must be thorough: no trace of application product must remain.
• Leave the equipment to dry.
At the start of a spraying campaign,
if there is worry about nocturnal freezing:
Operate in the same way, but with weak-
er concentrations.
Содержание VECTIS 1000
Страница 2: ......
Страница 8: ...May 2015 8 MACHINE IDENTIFICATION ...
Страница 40: ...May 2015 40 DECRIPTION OF THE MACHINE ...
Страница 112: ...May 2015 112 MACHINE MAINTENANCE ...
Страница 128: ...May 2015 128 ENVIRONMENTAL PROTECTION ...
Страница 129: ...May 2015 129 Chapter 8 8 PERSONAL NOTES ...
Страница 130: ...May 2015 130 PERSONAL NOTES ...