MENU NAVIGATION
DISPLAY REPORT
DISPLAY
DESCRIPTION
--
STAND BY
The control board is waiting for a command.
-.
REMOTE TRANSMITTING
A remote key is pressed. The display showing a dot.
5t
STOP
Stop input open ( Terminal block 2
Normally closed
,
E2
=
5t
).
Stop remote key pressed, stored using
r2
function.
tC
/
td
EXT. PHOTOCELL 1/2
External photocell input open ( Terminal blocks 3,4
Normally closed
,
E3
=
tC
/
tD
).
tA
INT. PHOTOCELL
Internal photocell input open ( Terminal block 4
Normally closed
,
E4
=
tA
).
FH
INT.+EXT. PHOTOCELLS
Ex Internal photocell inputs open.
Go
START
Start input closed ( Terminal block 1
Normally open
,
E1
=
Go
).
Start remote key pressed, stored using
r1
or
r4
functions.
PE
PEDESTRIAN
Pedestrian input closed ( Terminal block 7
Normally open
,
E7
=
PE
).
Pedestrian remote key pressed, stored using
r3
function.
oP
/
CL
OPEN / CLOSE
Open/Close input closed ( Terminal block 1,2,7
Normally open
,
E1
,
E7
=
oP
/
CL
).
Open/Close remote key pressed. Stored using programmable radio functions r6, r7, r8.
Po
/
PC
DEAD MAN OPEN/CLOSE
Dead man open/close input closed (Terminal block 1,7
Normally open
,
E1
,
E7
=
Po
/
PC
).
Dead man open/close remote key pressed. Stored using programmable radio functions.
FA
/
LA
OPENING LIMIT SWITCH
Opening limit switch open/closed ( Terminal block input 6
N.C/N.O.,
E6
=
FA
N.C.
/
LA
N.O.
).
FC
/
LC
CLOSING LIMIT SWITCH
Closing limit switch open/closed ( Terminal block input 5
N.C.
/
N.O.,
E5
=
FC
N.C.
/
LC
N.O.
).
1H
LIMIT SWITCHES ERROR
O Closing limit switches activated at the same time.
Eo
DOMUS INPUT
Domus input closed (Terminal block 1,7
Normally open
,
E1
,
E7
=
Eo
).
rt
RANGE TEST
Range test remote key pressed, stored using programmable radio functions.
EL
ELECTRIC-LOCK
Electric-lock input closed ( Terminal block 1,4,7
N.O.
E1
,
E4
,
E7
=
EL
)
.
Electric-lock remote key pressed. Stored using programmable radio functions.
oC
DOMUS REMOTE
Domus remote key pressed, stored using
H1
,
H2
,
H3
or
H4
(
DOMUS EXPANSION
).
0t
CONTROL BOARD DAMAGED
Control board damaged, replace it.
1t
PHOTOCELL ERROR
Parameter
t1
PHOTOCELLS TEST
is set to
SI
ENABLED
. The photocells test failed: wiring error,
installation error or damaged device.
9A
MOTOR ERROR
Parameter
t2
MOTOR TEST
is set to
SI
ENABLED
. The motor test failed: wiring error, thermal state,
burnt fuse, or damaged motor.
7A
OBSTACLE DETECTED
Parameter
A7
STANDARD OBSTACLE THRESHOLD
is enabled (set from
00
to
99
). An obstacle has
been detected during the
standard working time
A1
. Causes: obstacle on the gate pathway or tuning
error.
8A
SLOWDOWN OBSTACLE
DETECTED
Parameter
A8
STANDARD OBSTACLE THRESHOLD
is enabled (set from
00
to
99
). An obstacle has
been detected during the
slowdown working time
A2
. Causes: obstacle on the gate pathway or
tuning error.
FF
MEMORY FULL
You are trying to store a remote but the control board memory is full. The remote cannot be stored.
Erase a remote to save a new one (
r0
single erase or
r5
total erasing).
From
00
to
99
MOTOR STRESS
During opening and closing the display shows motor stress. The stress is shown as number from
00
OFF
to
99
MAX
.
www.tecnoautomazione.com