PROGRAMMING PROCEDURE
MOTOR
WORKING TIME
PROGRAMMING
YOU NEED:
•
START
Button
For saving a remote key as
START
, using buttons A/B to select
r1
. hold down the remote key
then press button C on the control board.
•
Check the motor direction.
•
Check if the terminal block inputs work properly.
P1
SETS:
•
A1
→
Motor A standard working time
•
A2
→
Motor A slowdown working time
•
F0
→ Automatic close time
P1
→
__
Select
P1
using buttons A/B. When display show
__
press
START
.
A1
Motor A opens. When the opening is almost complete press
START
to go the
next step.
A2
Motor A slows down. When the gate reaches the opening limit switch the control
board goes to the next step automatically. If you do not use the opening limit
switch, press
START
to go the next step.
F0
The motor is off. The flashing lamp is on. The display show the time lapsed.
When you want to close the gate press a
START
. The
automatic close time
will
be equal to the value shown on the display.
After the programming you can modify each parameter manually
P1
AUTOMATIC
PROGRAMMING
P3
YOU NEED:
•
START
Button
For saving a remote key as
START
, using buttons A/B to select
r1
. hold down the remote key
then press button C on the control board.
•
Check the motor direction.
•
Check if the terminal block inputs work properly.
•
The opening limit switch installed or mechanical gate stop in opening.
P3
SETS:
•
A1
→
Motor A standard working time
•
A2
→
Motor A slowdown working time
•
F0
=
10 seconds (
Auto-close time)
HOW-TO:
•
Select
P3
using buttons A/B. After a few seconds display shows
__
.
•
Press
START
→
The gate opens. When the gate reaches the opening limits switch or the ground stop the
control board stops the motor. The flashing lamp is on.
Display shows count-down from 10 to 0 seconds then gate starts closing.
If you do not use the opening limit switch and the control board does not detect the mechanical
gate stop
, press any input to terminate the programming. Set the control board parameters manually
or select the semi-automatic procedure
P1
.
www.tecnoautomazione.com
Pag. 14 / 17