![Tecno Automazione T011S Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/tecno-automazione/t011s/t011s_user-manual_1071655009.webp)
MOTOR
STANDARD WORKING
TIME
The opening and closing cycles are subdivided into two phases: The standard phase
A1
and the slowdown phase
A2
.
A1
→
Programs the duration of the standard phase, during this time the force of the motor is
A5
.
A2
→
Programs the duration of the slowdown phase, during this time the force of the motor is
A6
.
The slowdown phase is performed after the standard phase.
A1
→
0.0
to
9.9
and from
10
to
99
seconds.
A2
→
0.0
to
9.9
and from
10
to
99
seconds.
A1
SLOWDOWN WORKING
TIME
A2
START UP TIME
A3
is the start up time of the motor. During this time the force of the motor increases
constantly until it reaches the maximum power and the obstacle detection sensor is
disabled. Each time the motor starts, the first
A3
seconds are the start up time.
A3
→
0.1
to
1.5
seconds.
A3
STANDARD FORCE
A5
is the force of the motor during the standard working time
A1
. If
A5
increases, the
sensitivity of the sensor decreases. If
A5
decreases, the sensitivity of the sensor increases. It
is advisable to choose the required force of the motor first then calibrate the threshold
A7
.
A5
→
3
to
10
.
A5
SLOWDOWN FORCE
A6
is the force of the motor during the slowdown working time
A2
. If
A6
increases, the
sensitivity of the sensor decreases. If
A6
decreases, the sensitivity of the sensor increases. It
is advisable to choose the required force of the motor first then calibrate the threshold
A8
.
A6
→
6
to
10
.
A6
STANDARD OBSTACLE
DETECTION
THRESHOLD
This parameter will have effect during the standard working time
A1
. If the control board
detects a motor stress higher than
A7
, it means that there is an obstacle in the way of the
gate. The control board will make a decision in accordance with its programming as
described in
SENSOR OPERATING MODE
(see page 7).
When the motor is on and the standard working time is in progress, the control board display
shows the motor stress as number. You can use this value as a feedback value.
00
is the
minimum and
99
is the maximum. The maximum value can be lower than
99
. It depends on
the motor. To disable the standard obstacle detection function set
A7
=
no
. To set
no
hold down or keep pressing button C until the display shows
no
.
A7
is settable from
00
to
99
. After
99
the control board display shows
no
.
A7
→
00
to
99
and
99
to
no
(DISABLED).
A7
SLOWDOWN OBSTACLE
DETECTION
THRESHOLD
This parameter will have effect during the slowdown working time
A2
.
If the control board detects a motor stress higher than
A8
, it means that there is an
obstacle in the way of the gate. The control board will make a decision in accordance with its
programming as described in
SENSOR OPERATING MODE
(see page 7).
When the motor is on and the slowdown
A2
is in progress, the control board display shows
the motor stress as a number. You can use this value as a feedback value.
00
is the minimum
and
99
is the maximum. The maximum value can be lower than
99
. It depends on the motor.
To disable the slowdown obstacle detection function set
A8
=
no
. To set
no
hold down or
keep pressing button C until the display shows
no
.
A8
is settable from
00
to
99
. After
99
the control board display shows
no
.
A8
→
00
to
99
and
99
to
no
(DISABLED).
A8
MOTOR BRAKE
Motor brake is programmable by 0.01 seconds step. The motor brakes at the end of each
movement. It is useful to minimizing the inertia effects. During the slowdown motor brakes
only if the time lapsed is less than 2 seconds.
A9
→
no
DISABLED to
50
(0.5 seconds).
A9
www.tecnoautomazione.com
Pag. 7 / 17