CONNECTIONS
www.tecnoautomazione.com
Pag. 5 / 17
A1
..
A9
MOTOR
13
: CLOSE
14
: COMMON
15
: OPEN
FLASHING LAMP
24 VAC 20 WATT
INSTALLING OPTIONAL MODULES: DOMUS AND ELECTRIC-LOCK
POWER SUPPLY 230 VAC
E1
START
Go
, OPEN
oP
, CLOSE
CL
,
DEAD-MAN OPEN
Po
,
DEAD-MAN CLOSE
PC
, DOMUS
Eo
,
ELECTRIC-LOCK
EL
E2
DISABLED
no
, STOP
5t
,
OPEN
oP
, CLOSE
CL
E5
CLOSING LIMIT SWITCH N.C
.
FC
CLOSING LIMIT SWITCH N.A.
LC
E6
OPENING LIMIT SWITCH N.C
.
FA
OPENING LIMIT SWITCH N.A.
LA
E7
PEDESTRIAN
PE
, OPEN
oP
,
CLOSE
CL
, DEADMAN-OPENN
Po
,
DEAD-MAN CLOSE
PC
, DOMUS
Eo
,
ELECTRIC-LOCK
EL
PHOTOCELLS TRANSMITTER
E3
EXTERNAL PHOTOCELLS N.C.
tC
E4
DISABLED
no
INTERNAL PHOTOCELLS N.C.
tA
EACH INPUT CAN BE DISABLED
by settings its value to
no
. Inputs 2,3, and 4 have
auto-enable functionality
if the input is
disabled
(=
no
) and a normally closed contact is being wired to 2 – 8 , 3 – 8 , and 4 – 8 the control board sets inputs value to
5t
stop (2
–
8)
,
tC
external photocell logic 1 (3
–
8)
, and
tA
internal photocell (4
–
8)
.