57
The
Discharge
Valve (V1)
does
not open/close.
Motorized valve
malfunctioning.
Check if the rotation direction
of the actuator
(refer to the
FIRST START UP
PROCEDURE
section).
Set the rotation direction of the actuator
to Y2 (refer to the
FIRSAT START UP
PROCEDURE
section).
Check if the valve actuator
*
is
set in manual mode (refer to the
Manual opening activation for
motorized valves
section).
Set the actuator in the automatic mode
(refer to the
Manual opening activation
for motorized valves
section).
Check the correct installation
and electrical connections of the
Discharge Valve (V1).
Referring to attached flow and
connections diagrams, ensure the valve is
correctly installed and connected.
Check if manually operating the
three-way valve (refer to the
Manual opening activation for
motorized valves
section), the
valve rotation is blocked.
Unblock or replace the three-way valve.
Set the system in manual mode
and verify that when set valve
(V1) ON it will not activate
(refer to
Manual mode
section).
Repair or replace the motorized actuator.
Broken control box.
All previous checks have not
been successful.
Repair or replace the main control box.
The
Sludge
Discharge Valve
(V2)
does not
open/close.
Motorized valve
malfunctioning.
Check if the rotation direction
of the actuator
*
is correctly set
(refer to the
FIRST START UP
PROCEDURE
section).
Set the rotation direction of the actuator
to Y2 (refer to the
FIRSAT START UP
PROCEDURE
section).
Check if the valve actuator
*
is
set in manual mode (refer to the
Manual opening activation for
motorized valves
section).
Set the actuator in the automatic mode
(refer to the
Manual opening activation
for motorized valves
section).
Check the correct installation
and electrical connections of the
Discharge Valve (V2).
Referring to attached flow and
connections diagrams, ensure the valve is
correctly installed and connected.
Check if manually operating the
three-way valve (refer to the
Manual opening activation for
motorized valves
section), the
valve rotation is blocked.
Unblock or replace the three-way valve.
Set the system in manual mode
and verify that when set valve
(V2) ON it will not activate
(refer to
Manual mode
section).
Repair or replace the motorized actuator.
Broken control box.
All previous checks have not
been successful.
Repair or replace the main control box.
13.1.1
Manual opening activation for motorized valves
When the Discharge Valve (V1), the Sludge Discharge Valve (V2) or both the valves ore blocked or do not automatically open
for any other cause, it will be necessary to perform a Valve Manual Opening procedure on the valve that faults.
To perform a Valve Manual Opening procedure follow the steps, listed below:
1.
Press the appropriate black button on the top of the actuator and block it in this position (refer to figure below);
2.
Then work manually on the lever of the valve and turn it manually, using the lever extension supplied with the plant;
3.
Finally reset the actuator in automatic mode by pressing and release the black button (refer to figure below).
*
For every ECOmar S model, except ECOmar 545 S. For ECOmar 545 S ignore this step.
Содержание ECOmar 145 S
Страница 45: ...45 12 1 1 Macerating Discharge pumps performance curves Fig 12 1 1 1 C30 50Hz performances ECOmar 20 32 S ...
Страница 46: ...46 Fig 12 1 1 2 C30 60Hz performances ECOmar 20 32 S ...
Страница 47: ...47 Fig 12 1 1 3 S42 50Hz performances ECOmar 45 70 145 S ...
Страница 48: ...48 Fig 12 1 1 4 S42 60Hz performances ECOmar 45 70 145 S ...
Страница 79: ...79 ...