- 10 -
3.01 Proper Installation, WY & HY Belt Scale Models
Proper scale installation is critical for high accuracy and repeatability. A properly mounted scale
should be located on a rigid, horizontal conveyor. If the conveyor is at an incline, assure it is not
so steep that material rolls back on itself causing it to be weighed twice. The belt and idlers
should move smoothly and the scale should be mounted in an area free of extreme temperature,
wind and vibration. The shimming and aligning of the idlers surrounding the scale is extremely
critical, because the weigh area must be slightly raised above the other idlers as indicated below.
Avoid the following!
•
Badly worn belts and splices
•
Joined belts with different thickness
•
Poor belt training or alignment
•
Wind, temperature, or vibration extremes
•
Material build-up on belt, idlers or calibration weights
•
Loosely mounted unstable conveyor
•
Idlers with steep trough angles
•
High belt tension
•
Steep conveyors allowing material to roll back
•
Belt skirting or other interference near scale
CHAPTER 3 – SCALE INSTALLATION
Содержание Tecweigh 20
Страница 2: ... 1 ...
Страница 10: ... 9 2 09 I O Quick Reference Guide ...
Страница 20: ... 19 ...
Страница 24: ... 23 4 03 WY15 and WY25 Scale Wiring load cells ...
Страница 25: ... 24 4 04 HY15 and HY25 Field Wiring ...
Страница 26: ... 25 4 05 WY10 WY10HD and WY20 Scale Wiring LVDTs ...
Страница 27: ... 26 4 06 Chart Recorder Data Logger using the 4 20 ma output ...
Страница 28: ... 27 4 07 Chart Recorder Data Logger using the HFR output ...
Страница 29: ... 28 4 08 Remote Rate Total Display 4 09 Remote Tons Counter ...
Страница 30: ... 29 4 10 Radio Transceivers Local Scale Remote Processor ...
Страница 31: ... 30 4 11 Radio Transceivers Local Processor Remote PLC PC or Remote Display ...
Страница 32: ... 31 4 12 Radio Transceivers Local DC Generator Remote Processor ...
Страница 33: ... 32 4 13 Radio Transceivers Local DC Generator and Processor ...
Страница 34: ... 33 4 14 Multiple Processors to Tecweigh Multi Scale Display MSD ...
Страница 35: ... 34 4 15 Interposing Relay External 120 vac Power 4 16 Interposing Relay Internal 30 vdc Power ...
Страница 61: ... 60 SC300 PCB WY15 and WY25 SC400 PCB WY10 and WY20 ...
Страница 71: ... 70 10 01 WY10 Dimensions CHAPTER 10 DIMENSIONS ...
Страница 72: ... 71 10 02 WY10 HD Heavy Duty Dimensions ...
Страница 73: ... 72 10 03 WY15 Dimensions ...
Страница 74: ... 73 10 04 WY20 Dimensions ...
Страница 75: ... 74 10 05 WY25 Dimensions ...
Страница 76: ... 75 10 06 HY15 and 25 Dimensions ...