User's manual for
Register Write
Range
Register description
0x0210
No
-
Door width in pulses, high byte
0x0211
No
-
Door width in pulses, low byte
0x0212
No
200 ÷ 3999 „
Width
”
parameter in
„
Doors data
” menu, in [mm]
0x0213
No
10 ÷ 399
„
Weight
”
parameter in
„
Doors data
” menu, in [kg]
0x0214
No
0 ÷ 79
„
V opening
”
parameter in
„
Speeds
” menu, in [cm/s]
0x0215
No
0 ÷ 79
„
V closing
”
parameter in
„
Speeds
” menu, in [cm/s]
0x0216
No
50 ÷ 999
„
Init. speed
”
parameter in
„
Calibration
” menu, in [0.1%]
0x0217
No
-
Acceleration/deceleration speed of door opening
0x0218
No
-
Acceleration/deceleration speed of door closing
0x0219
No
-
Start point of deceleration while opening in [mm]
0x021A
No
-
Start point of deceleration while closing in [mm]
0x021B
No
0 ÷ 299
„
Lock zone
” parameter in „
Calibration
” menu, in [mm]
0x021C
No
0 ÷ 1
„
OPENING inp.
” parameter in „
Inputs
” menu:
0
– inactive;
1
- active;
0x021D
No
0 ÷ 1
„
CLOSING inp.
” parameter in „
Inputs
” menu:
0
– inactive;
1
- active;
0x021E
No
0 ÷ 1
„
OPEN switch
” parameter in „
Calibration
” menu:
0
– inactive;
1
- active;
0x021F
No
0 ÷ 2
„
OPEN output
” parameter in „
Outputs
” menu:
0
– inactive;
1
- normal open;
2
- normal closed
0x0220
No
0 ÷ 2
„
CLOSED outp.
” parameter in „
Outputs
” menu:
0 –
inactive;
1
- normal open;
2
- normal closed
0x0221
No
0 ÷ 2
„
BARRIER out.
” parameter in „
Outputs
” menu:
0
– inactive;
1
- normal open;
2
- normal closed
0x0222
No
0 ÷ 2
„
External
” parameter in „
Photocell
” menu:
0
– inactive;
1
– transfer;
2
- active
0x0227
No
0 ÷ 1
„
INSTALL inp.
” parameter in „
Inputs
” menu:
0
– inactive;
1
- active;
0x0228
No
-
Additional input (not used)
0x0229
No
0 ÷ 1
„
Language
” parameter in „
Region
” menu:
0
– Polish;
1
- English;
0x022A
No
0 ÷ 5
„
Lock. speed
” parameter in „
Calibration
” menu:
0
– MIN.;
1
– 20% …
5
– 100%
0x022B
No
0 ÷ 99
„
Force reduc.
”
parameter in
„
Calibration
” menu, in [%]
0x1004
Yes
see desc.
Write only register
, allows to door control while RS-485 mode:
0
– open,
0x100
– close,
32