Fig. 3.5. Connection of the controller while using both inputs
Application of voltage to the
{OPEN INP.}
opening procedure. During that, until the door is fully open (until the
{OPEN}
relay output is
active) removal of the voltage from
{OPEN INP.}
door movement in order to close it. Removal of the voltage from
{OPEN INP.}
input after the
door has fully opened will not initiate the closing procedure and the door will remain open.
Application of voltage to the
{CLOSE INP.}
closing procedure. During that, until the door is fully closed (until the
{CLOSED}
relay output is
active) removal of the voltage from
{CLOSE INP.}
door movement in order to open it. Removal of the voltage from
{CLOSE INP.}
input after the
door has fully closed will not initiate the opening procedure and the door will remain closed.
Voltage should not be applied to both control inputs at the same time. If it is, however,
the
{CLOSE INP.}
will behave as if only voltage was applied to
{CLOSE INP.}
input.
Figures 3.6 A and B shows how to connect the control inputs in systems where only one
output is used by the main elevator controller to control door's opening and closing. Figure
3.6A shows how to connect the
{OPEN INP.}
and figure 3.6B shows connection in case of using voltage output on the elevator's main
controller.
A)
B)
Fig. 3.6. Connection of the controller while using single
{OPEN INP.}
input
Make sure that ONLY one input -
{OPEN INP.}
this type of control. In this mode, if the voltage is applied to the
{OPEN INP.}
will open the door and keep it open as long as the voltage remains applied. Removal of the
voltage from the
{OPEN INP.}
input will make the controller close the door.
{CLOSE INP.}
input only as shown in
fig. 3.7 A and B. For this purpose only the
{CLOSE INP.}
input must be activated in the
controller's menu. In this case the application of voltage to
{CLOSE INP.}
input will make the
10
J9
J8
1
2
3
4
5
1
2
OPEN INP.
CLOSE INP.
+ -
external
supply
0V
J9
J8
1
2
3
4
5
1
2
OPEN INP.
CLOSE INP.
+15V
J9
J8
1
2
3
4
5
1
2
OPEN INP. / CLOSE INP.
+15V
J9
J8
1
2
3
4
5
1
2
+ -
external
supply
0V
OPEN INP. / CLOSE INP.