TechWind SDK-500 Скачать руководство пользователя страница 2

User's manual for 

elevator door controller 

SDK-500

Copyright

Copyright © 2007,TechWind. All rights reserved.

This document may not be copied or otherwise reproduced, in whole or in part, except
as specifically permitted under international copyright law, without the prior
written consent from TechWind.

Disclaimer

THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. 
TechWind  ASSUMES NO RESPONSIBILITY FOR INACCURACIES OR OMISSIONS AND 
SPECIFICALLY   DISCLAIMS   ANY   LIABILITIES,   LOSSES,   OR   RISKS,   PERSONAL   OR 
OTHERWISE, INCURRED AS A CONSEQUENCE, DIRECTLY OR INDIRECTLY, OF THE 
USE OR APPLICATION OF ANY OF THE CONTENTS OF THIS DOCUMENT. FOR THE  
LATEST   DOCUMENTATION,   CONTACT   YOUR   LOCAL   SUPPLIER   OR  TechWind 
COMPANY.

This   publication   may   contain   examples   of   screen   captures   and   reports   used   in   daily 
operations.   Examples   may   include   fictitious   names   of   individuals   and   companies.   Any 
similarity to names and addresses of actual businesses or persons is entirely coincidental. 

Trademarks and 

patents

TechWind name and logo are registered trademarks of TechWind company.
SDK-500 product and logo are registered trademarks of TechWind company.
Other trade names used in this document may be trademarks or registered trademarks of the 
manufacturers or vendors of the respective products.

Software license

agreement

Software and firmware supplied with products is proprietary and furnished under license and 
can be used or copied only in accordance with the license terms.

THE   ENCLOSED   PROGRAM   IS   FURNISHED   SUBJECT   TO   THE   TERMS   AND 
CONDITIONS OF THIS AGREEMENT. RETENTION OF THE PROGRAM FOR MORE THAN 
30   DAYS,   OPENING   OF   THE   SEALED   WRAPPER,   IF   ANY,   SURROUNDING   THE 
PROGRAM,   OR   USE   OF   THE   PROGRAM   IN   ANY   MANNER   WILL   BE   CONSIDERED 
ACCEPTANCE   OF   THE   AGREEMENT   TERMS.   IF   THESE   TERMS   ARE   NOT 
ACCEPTABLE,   RETURN   THE   UNUSED   PROGRAM   AND   ANY   ACCOMPANYING 
DOCUMENTATION TO  TechWind FOR A FULL REFUND OF THE LICENSE FEE PAID.

Intended use

Use this product only for the purpose it was designed for; refer to the data sheet and   user 
documentation. For the latest product information, contact your local supplier or visit us onlin e 
at www.

 

 techwind

 

 .pl

   

European directives

The   European   directive   “Waste   Electrical   and   Electronic   Equipment” 
(WEEE)   aims   to   minimise   the   impact   of   electrical   and   electronic 
equipment waste on the environment and human health. To conform with 
this directive, electrical equipment marked with this symbol must not be 
disposed   of  in   European   public   disposal   systems.   European   users   of 
electrical equipment must now return end-of-life equipment for disposal. 
Further   information  can   be   found   on   the   following   website: 
www.recyclethis.info.

2

Содержание SDK-500

Страница 1: ...ator door controller type SDK 500 firmware version 1 21 0 Read the user s manual carefully before starting to use the unit TechWind company reserves the right to introduce changes without prior notice...

Страница 2: ...demarks of the manufacturers or vendors of the respective products Software license agreement Software and firmware supplied with products is proprietary and furnished under license and can be used or...

Страница 3: ...485 INTERFACE 14 3 12 EMERGENCY BATTERY POWER SUPPLY BUTTON 14 4 CONTROLLER PROGRAMMING 15 4 1 PROGRAMMING MENU 15 4 2 EDITING PARAMETERS 16 4 2 1 Numeric parameters 16 4 2 2 Switch parameters 16 4 3...

Страница 4: ...f this device proper transport storage and assembly as well proper operation and professional maintenance is required TechWind disclaims responsibility for property damage or personal injuries resulti...

Страница 5: ...ing force and reverse force Incorrect settings too high of current value corresponding to tightening force may cause damage to the motor SDK 500 menu allows for setting of the current corresponding to...

Страница 6: ...ctly required to provide good grounding of controller metal housing and transformer cover using separate grounding wire to appropriate grounding terminal Motor and encoder wires must be shielded and f...

Страница 7: ...2 3 1 1 2 3 4 5 1 2 3 4 1 2 3 4 5 1 2 ENCODER 24V AC 24V AC 0V 24V DC BATTERY AC POWER SUPPLY 0V SIGNAL B SIGNAL A 5V ENCODER MOTOR2 MOTOR1 EKRAN MOTOR 0V B A 5V RS 485 OPEN INP CLOSE INP END SWITCH I...

Страница 8: ...sible An automatic battery charger circuitry is a part of the controller board and is designed to charge battery with 200 mA current which is sufficient to keep the battery fully charged but will not...

Страница 9: ...9 connector the encoder can be connected directly to the SDK 500 board s screw terminals as shown in figure 3 4B 3 6 CONTROL INPUTS The SDK 500 controller is equipped with two control inputs provided...

Страница 10: ...s and the SDK 500 will behave as if only voltage was applied to CLOSE INP input Figures 3 6 A and B shows how to connect the control inputs in systems where only one output is used by the main elevato...

Страница 11: ...indicate detection of an obstacle during the door movement It is activated both in case of the optical barrier interruption as wells as in case of a mechanical blocking of the door movement Note that...

Страница 12: ...troller unit or from the external optical barrier power supply A B Fig 3 9 External optical barrier connection CAUTION With the barrier not interrupted the voltage must at all times be applied to the...

Страница 13: ...LL input is enabled by default 3 10 OPTIONAL TERMINAL POSITION CONTACT DOOR OPEN Figure 3 11 shows the connection of the optional terminal position contact NO type contact connected to the END SWITCH...

Страница 14: ...WER SUPPLY BUTTON RUN ON BATTERY button allows to switch on the emergency battery power supply The SDK 500 controller is equipped with the input for back up battery power supply connection It allows t...

Страница 15: ...nu options Entering of the passwords is similar to the edition of numeric parameters After entering of last digit of the password first menu position will be displayed if the password is correct or Wr...

Страница 16: ...on the list can be selected for the given parameter Options of switching parameter are selected using buttons Short pressing of ENTER displays confirmation question message Save changes Select the an...

Страница 17: ...er mode Parameter edition MENU ESC MENU ESC 5 Inputs MENU ESC 5 3 INSTALL inp 5 2 CLOSING inp ENTER ENTER MENU ESC ENTER 5 1 OPENING inp Parameter edition MENU ESC 8 Access setup 4 2 Door number MENU...

Страница 18: ...he door the controller will display Kinetic energy exceeded message and automatically adjust maximum speed such as to account for the new weight setting 2 Speeds 2 1 V Opening range 0 10 0 79 m s Requ...

Страница 19: ...nnectors see figure 6 1 at page 29 After changing motor power supply connection Installation procedure must be start again During this movement terminal positions of the door will be identified and st...

Страница 20: ...is moved away from the obstacle the controller will attempt to close open the door once again If the obstacle is still in the door s way the procedure will be repeated up to 5 times If the obstacle i...

Страница 21: ...losed door is tighten continuously power supply of motor is always on by CLOSING input closed door is tighten only if voltage is provided to the CLOSE INP input Removal of the voltage from CLOSE INP i...

Страница 22: ...dirt and mechanical factors will cause additional movement resistance which will influence the current value As the controller is monitoring current has a chance to detect and signal maintenance need...

Страница 23: ...each ENTER pressing will close and open doors alternately 4 2 Door number range 0 3 Used in multi door installation It corresponds to the address of the SDK 500 controller and is used in systems driv...

Страница 24: ...options inactive normal open normal closed The relay connected to the output is not controlled when this option is set to inactive If set to normal open the relay will be in the closed state after the...

Страница 25: ...0 999999 Setting the password to 000000 allows free access to the menu Once any other password is selected and stored it will be asked each time the menu is started There is no way to recover a lost p...

Страница 26: ...INP input state is low CLOSE INP input state is high 5 1 NORMAL OPERATION Following screens are available during the normal operation SCREEN 1 line1 line2 producer name door state information initiali...

Страница 27: ...SCREEN 7 line1 line2 door closing current force in A door opening current force in A SCREEN 8 line1 line2 present temperature of the controller executable components in C permissible temperature of t...

Страница 28: ...ayed In case your password is forgotten please contact TechWind to receive new one use password Once the one use password is entered the message Enter new password is displayed User must enter new pas...

Страница 29: ...ters characterising the door and its drive See the Controller programming section at page 15 for details CAUTION Entering wrong parameters i e not corresponding to actual door and drive characteristic...

Страница 30: ...start bit 8 data bits 1 or 2 stop bits no parity control baud rate 19200 bit sec protocol Modbus RTU device address 0x18 N where N means value of Door number parameter All device parameters are availa...

Страница 31: ...No Parameters structure version hexadecimal 0x0201 No 0 1 One use password state 0x0202 No 0x18 0x1B Controller address interface SLAVE 0x0203 No 4 Baud rate 0x0204 No 0 1 Permission of registers writ...

Страница 32: ...0 1 OPENING inp parameter in Inputs menu 0 inactive 1 active 0x021D No 0 1 CLOSING inp parameter in Inputs menu 0 inactive 1 active 0x021E No 0 1 OPEN switch parameter in Calibration menu 0 inactive 1...

Страница 33: ...zone length 4 0 cm 21 3 A Lock speed Locking speed MIN 2 5 cm s 21 3 C Threshold Permissible percentage exceedance of the average current value of opening closing cycle 35 22 3 E Pause time Delay of...

Страница 34: ...xternal devices 15V DC 10 max 100 mA stabilized Communication interface option RS 485 8N1 and 8N2 Modbus RTU not separated Baud rate 19200 bit sec Display LCD alphanumeric 2 x 16 characters backlit Da...

Страница 35: ...User s manual for elevator door controller SDK 500 35...

Страница 36: ...TechWind Sp z o o Miszewko D browa 6 PL 80 297 Banino k Gda ska Poland tel 48 58 684 86 19 20 fax 48 58 684 86 17 http www techwind pl e mail biuro techwind pl...