3.7.6 Alarm Output
Do not connect alarm output port directly with high power load (no more than 1 A) in
case of heavy current.
You can use the co-contactor to realize the connection between the alarm output port
and the load.
Please refer to Figure 3-6 for more information.
Figure 3-6
3.7.7 Alarm Input and Output Details
You can refer to the following sheet and Figure 3-7 for alarm input and output
information.
Parameter
Grounding Alarm
Ground Ground
line
Alarm Input
1, 2, …, 16
Relay Output
1,2,3,4: NO and C(Normally Open and Com)
5: NO,C and NC(Normally Open, Com, Normally Closed)
6: Ctrl 12V(This is used for reset the senor)
485 A
、
B
485 communication port. They are used to control devices
such as PTZ.
+12
(
C
)
This should input an external power input.
4/8/16-ch grounding alarm inputs. (Normal open or Normal close type)
Please parallel connect COM end and GND end of the alarm detector (Provide
external power to the alarm detector).
Please parallel connect the Ground of the DVR and the ground of the alarm
detector.
Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
If you need to reset the touched-off alarm remotely, you can use DVR to supply
controllable 12 V power to the alarm detector such as the smoke detector.
Use the same ground with that of DVR if you use external power to the alarm
device.
29
Содержание DVR-LT016480
Страница 1: ...Standalone DVR User s Manual 1...
Страница 13: ...13...
Страница 19: ...Figure 2 3 2 2 2 Connection Sample Here is a connection sample for your reference See Figure 2 4 Figure 2 4 19...
Страница 44: ...Figure 4 15 Figure 4 16 Figure 4 17 44...
Страница 86: ...Figure 5 50 86...
Страница 91: ...Figure 6 11 91...
Страница 110: ...Figure 7 32 Mul DDNS Here you can select DDNS type This operation needs DVR device supported See Figure 7 33 110...
Страница 115: ...Figure 7 39 Figure 7 40 Figure 7 41 115...
Страница 130: ...Add organization structure Add device Figure 8 5 130...