Annex D SPN of DUT-E S7 Radiobox RS Functional modules / Vehicle power supply FM
DUT-E S7 fuel level sensor. Operation manual. Version 4.0
©
Technoton, 2021
77
Table D.4
—
Vehicle power supply FM. Displayed and/or editable SPN
with the help of Service S6 DUT-E software
SPN
Name
Factory
value
Unit of
measure
Range
Clarification
Vehicle power supply status
Vehicle Power
Supply Voltage
On the fact
V
0…3212.75
Shows current value of ON voltage.
/2.9
Vehicle Power
Supply
Voltage/
2.9 Average
For 5 Minutes
On the fact
V
0…3212.75
Shows average value of ON voltage within previous
5 minutes.
Vehicle Power
Supply Status
On the fact
No
Off/
Lowe level/
Accumulator/
Starter/
Generator/
High level
Shows current mode of ON in accordance with user-defined
borders of ON voltage levels of Vehicle
(see figures D.4 and D.5).
Vehicle Power
Supply
Presence
On the fact
No
On/Off
Displays the current state of the board (On/Off) in
accordance with the user-set voltage level of the TC system
trip (see figures D.4 and D.5).
Power supply borders
Nominal
Battery
Voltage
24
V
0…60
Field for entering a nominal value of accumulator voltage of
Vehicle (U
nom
=12V/24V) (see figures D.4 and D.5).
High Voltage
Level
1.29
-
0…1.99
Field for entering value of high voltage level of onboard
network (1.29▪U
nom
) (see figures D.4 and D.5).
Entered value of voltage is used as a threshold for recording
"Faulty ON" Event.
Generator
Voltage
Level
1.16
-
0…1.99
Field for entering value of voltage level of generator, i.e.
when engine of Vehicle is running (1.16▪U
nom
)
(see figures D.4 and D.5).
Engine
Starter
Voltage
Level
0.91
-
0…1.99
Field for entering value of voltage level starter is running, i.i
when Vehicle’s engine is starting (0.91▪U
nom
)
(see figures D.4 and D.5).
Low Voltage
Level
0.75
-
0…1.99
Field for entering value of low voltage level of ON
(0.75▪U
nom
). Entered value of voltage is used as a threshold
for recording "Faulty ON" Event.
(see figures D.4 and D.5).
Battery Off
Level
0.20
-
0…1.99
Field for entering value of voltage level when ON switches
off (0.20▪U
nom
).
(see figures D.4 and D.5).
Engine
Starter
Continues
Working
Time Limit
30
s
5…30
Field for entering value of starter’s permissible time of
continuous operation, above which the starter may fail
(see figures D.4 and D.5).
Entered value is used as a threshold for recording
"Exceeding permissible time of continuous operation of
starter" Event.
Vehicle power supply. Counts
Vehicle
hours of
operation on
power supply
On the fact
s
0…4211080000
Counter of total operating time of Vehicle from onboard
network since Unit installation to the Vehicle. User cannot
reset the value of this Counter
*
.
Vehicle
hours of
operation
from battery
On the fact
s
0…4211080000
Counter of total operating time of Vehicle from
accumulator since Unit installation to the Vehicle. User
cannot reset the value of this Counter
*
.
Starter
hours of
operation
On the fact
s
0…4211080000
Counter of total operating time of starter since Unit
installation to the Vehicle. User cannot reset the value of
this Counter
*
.
Starter
hours of
operation
On the fact
s
0…4211080000
Counter of total operating time of Vehicle’s engine since
Unit installation to the Vehicle. User cannot reset the value
of this Counter
*
.
*
of