![Technoton DUT-E S7 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/technoton/dut-e-s7/dut-e-s7_operation-manual_1070695060.webp)
DUT-E S7 Radiobox RS wireless interface / Configuration / Establishment of communication with DUT-E S7 wireless sensors
DUT-E S7 fuel level sensor. Operation manual. Version 4.0
©
Technoton, 2021
60
7.6.3 Establishment of communication with DUT-E S7 wireless sensors
Service S6 DUT-E software enables to configure the connection of
wireless fuel level sensors (up to 2 pcs.) by means of
To establish a connection with DUT-E S7 and to receive data from it, you need to perform the
following actions:
1)
In the submenu of
Base S7 FM
) select the required sensor, in accordance with its
serial number, from the
Available Bluetooth Device List
. The above-mentioned list contains
MAC addresses of sensors (up to 15) that are currently visible (accessible) for the BLE-module
of DUT-E S7 Radiobox RS.
2)
Copy the selected sensor by drag-and-drop to the
Allowed Units S7 List
(see figure 33 a).
During the operation using S7 Technology each sensor is automatically assigned the ordinal
number of its network address: 101 and 102, for its identification.
In the appearing window
Add Unit
its serial number and network address are displayed for the
sensor added (see figure 33 b).
For each sensor added to the
Allowed Units S7 List
the possibility of operation using
S7 Technology is determined, in accordance with its accessibility status (
Enable/Disable
).
WARNINGS:
1)
After adding the sensor into the
Allowed Units S7 List
, you must save the
modified profile of DUT-E S7 Radiobox RS in the Unit. Then, after switching off
DUT-E S7 Radiobox RS, you may establish a connection directly with the added sensor
and configure its profile.
2)
You may add two DUT-E S7 wireless sensors at a maximum into the
Allowed Units S7 List
.
3)
In case DUT-E S7 sensor is deleted from the
Allowed Units S7 List
, its settings are
not deleted, but are stored in the non-volatile memory of DUT-E S7 Radiobox RS.
4)
In case the sensor from the
Allowed Units S7 List
is replaced by another one, you
need to re-configure the profile for the sensor added.
a) addition of a sensor for connection by
means of S7 Technology
b) displaying the network address and the
serial number of the sensor added
Figure 33
—
Configuration of DUT-E S7 Radiobox RS
for operation with DUT-E S7 wireless
sensors by means of S7 Technology