2.3.6 Calibration of fuel tank 

 

Fuel Tank Monitor app recalculates the measured value of fuel level into the fuel volume in the 
tank  according  to  the  calibration  table.  To  set  up  calibration  table  it  is  required  to  carry  out 

calibration of fuel tank

Calibration procedure is a sequence of fuel fillings by fixed portions from empty to full state of 
the fuel tank (see video 

Fuel level DUT-E installation

). 

IMPORTANT: 

To  measure  the  volume  of  fuel  portions  it  is  necessary  to  use 

measuring reservoir with inaccuracy not more than 0.25 %. 

To  make  fuel  tank  calibration  correctly,  where  the  sensor  is  installed,  it  is  required  to  follow 
the procedure: 

 

the 

Vehicle

 should not be loaded and stand on the flat horizontal surface; 

 

fuel tank should be empty; 

 

the vehicle wheels must be of standard size; 

 

the tire pressure should match with the prescribed for this Vehicle; 

 

the vehicle should not move, ignition off, engine off; 

 

pause  between  fuel  fillings  by  portions  into  the  tank  should  be  not  less  than 
60 seconds. 

 

Tank calibration table is stored in memory of 

specific

 Android device using Fuel Tank Monitor 

app (

Settings

 submenu, 

Tank

 tab) (see figure 15). 

 

 

 

Figure 15 

 Example of the tank calibration table generation using 

the Fuel Tank Monitor application 

 

Current indication 

of the sensor 

 

Содержание DUT-E S7

Страница 1: ...FUEL LEVEL SENSOR DUT E S7 OPERATION MANUAL Version 4 0 ...

Страница 2: ...2 2 3 2 Establishment of communication between the sensor and the Android device 24 2 3 3 Interface of Fuel Tank Monitor application 26 2 3 4 Operations with the sensor Profile 27 2 3 5 Calibration of the measuring system 28 2 3 6 Calibration of fuel tank 30 2 3 7 Adaptation of indications for specific conditions of exploitation 33 2 3 8 Monitoring of indications using the Android device 37 2 3 9 ...

Страница 3: ...less sensors 61 8 Packaging 63 9 Storage 64 10 Transportation 65 11 Utilization re cycling 66 Contacts 67 Annex A Template of check test report 68 Annex B Electromagnetic compatibility of BLE module 69 Annex C Explosion protection of DUT E S7 70 Annex D SPN of DUT E S7 Radiobox RS Functional modules 71 D 1 Self diagnostics FM 71 D 2 Fuel level sensor FM 73 D 3 Fuel level control FM 75 D 4 Vehicle ...

Страница 4: ...tions and the delivery set are updated 3 0 01 2020 OD Information on DUT E S7 Radiobox RS wireless interface and its use together with DUT E S7 wireless fuel level sensors is added 4 0 02 2021 OD Significant changes in the Fuel Tank Monitor mobile application are reflected new interface design function of automatic defining the remaining distance of the route function of summation of the fuel volu...

Страница 5: ...bsite Part S6 Data Base Part S6 Functional modules JV Technoton Website Part Technical support Part Software Firmware YouTube Technoton ORF 4 Website DUT E DUT E 2Bio DUT E GSM Installation manual CAN j1939 S6 Telematics interface Operation manual Technoton Engineering Website Page S7 Technology Page GNOM S7 Page DUT E 2Bio Page CANUp Page DFM S7 Page DUT E S7 Page S6 Technology ORF 5 Website ...

Страница 6: ...oftware refer to CAN j1939 S6 Operation manual PGN Parameter Group Number is a combined group of S6 parameters which has common name and number Functional modules FM of the Unit can have input output PGNs and setup PGNs SPN Suspect Parameter Number informational unit of S6 Each SPN has determined name number extension data type and numerical value The following types of SPN exist Parameters Counte...

Страница 7: ... terminal Tracking device Telematics unit is a unit of Telematics system used for reading the signals of Vehicle standard and additional sensors getting location data and transmitting the data to the Server Telematics system complex solution for vehicle monitoring in real time and trip analysis The main monitored characteristics of the vehicle Route Fuel consumption Working time technical integrit...

Страница 8: ... features wireless transmission of data using S7 Technology via Bluetooth Low Energy channel simultaneously to many receiving devices Android based smartphones tablets the Telematics terminal the display in the driver s cabin operation in the advertising mode BLE radio continuous transmission of measurement results with no need of integration with receiving devices ultra low power consumption prov...

Страница 9: ...ing possibility to avoid unauthorized intrusion and tampering ergonomic grooves in body allow comfortable grip of sensor s head when fastening it in bayonet mounting plate high quality technical support and documentation conformity with European and national automotive standards See figure 2 for identification codes for DUT E S7 ordering Figure 2 DUT E S7 order identification codes Example of DUT ...

Страница 10: ...lly the time left before the tank is filled during the fuelling operation Monitor the received signal strength indicator RSSI and the time of the latest message reception from the sensor Monitor the current mode of the sensor operation Monitor the sensor malfunctions Receive the sensor ID data serial number firmware version MAC address of BLE module Record log current values of the measuring gener...

Страница 11: ... sensor operation with ultra low power consumption The BLE module transmitter switches on automatically once in 5 s to transmit the current indications Such a mode of operation enables the sensor to operate completely independently during no less than 5 years without using any external power sources power is supplied only from the inbuilt battery Data from DUT E S7 can be received at a distance of...

Страница 12: ...l volume monitoring in fixed tanks Figure 4 Application areas of DUT E S7 Due to the availability of the inbuilt BLE module in DUT E S7 up to 8 wireless fuel level sensors can operate using S7 Technology together with CANUp 27 Pro Telematics gateway this enables to monitor in real time accurate current value of fuel level and fuel volume in tank accurate volume of fuel fill ups and drains fuel tem...

Страница 13: ...kit 1 pc including a bottom stop 1 pc b plastic mounting plate 1 pc c rubber gasket 2 pcs d sealing rubber ring 2 pcs e bolt 5 pcs f threaded rivet 5 pcs g self tapping screw 5 pcs h plastic seal 2 pcs i sealing cord 2 pcs j pattern of mounting holes location 1 pc Figure 5 DUT E S7 delivery set 1 pc is for initial DUT E S7 mounting and 1 pc as a spare part The delivery set may include just 1 gaske...

Страница 14: ...sing S7 Technology and built in battery see figure 6 Measuring part 2 of the sensor composed of two coaxial tubes that form condensate coating Changes of sensor electrical capacity depend on the diving depth of measuring probe into fuel dielectric liquid according to its properties WARNING Capacitive principle ensures highest accuracy of liquid measurement when the liquid has constant dielectric p...

Страница 15: ...ore than 1 0 Wireless data transfer interface Bluetooth 4 1 Transmitter power Tx Power dBm 4 Maximum distance between sensor and receiving device m 20 if mounted on a Vehicle or in indoor locations 50 when mounted within line of sight range Data transfer interval s 5 Estimated lifetime of the sensor battery life years 5 Maximum cutting of the measuring probe up to any length required Maximum lengt...

Страница 16: ...0x06 0xXX 0xFF 0xFFFF 0xXX 0xXXXX Figure 7 Structure of data packet transmitted by DUT E S7 The application layer of the output message protocol of DUT E S7 conforms with S6 Database see table 2 Table 2 Data composition of DUT E S7 output message Field number Length Parameter Name Fuel Level Sensor RAW Data PGN 63277 0xF72D 1 4 bytes SPN 521440 Frequency Hz 2 1 byte SPN 521457 Temperature C 3 2 by...

Страница 17: ...le 4 Attributes for calculation of current values of DUT E S7 parameters Parameter Factor Resolution Offset SPN 521440 0 001 0 Hz SPN 521457 1 50 C SPN 5347 0 01 320 m s SPN 5348 0 01 320 m s SPN 5349 0 01 320 m s The fuel level value Lact may be calculated according to the formula G 2 Lact Ls F1 F0 Fact 1 F0 F1 mm 2 where Ls length of the sensor measuring probe after cutting mm F0 frequency of th...

Страница 18: ...r and other devices for data receiving logging and displaying which have Bluetooth 4 X and high Recommendations on wireless connection of DUT E S7 to Telematics terminals can be obtained upon request at Technoton technical support service by e mail support technoton by RECOMMENDATION The best compatibility with DUT E S7 sensor during its operation using S7 Technology is provided by CANUp 27 Pro 3G...

Страница 19: ...ations of DUT E S7 Technical specifications Overall dimensions DUT E S7 fuel level sensor Operation manual Version 4 0 Technoton 2021 19 1 4 4 Overall dimensions Figure 8 DUT E S7 overall dimensions Nominal measuring probe length 700 mm 1000 mm ...

Страница 20: ...ertified specialists who have passed corporate technical training ATTENTION Strictly follow safety rules of automobile repair works as well as local safety rules of the customer company when mounting sensor 2 1 Exterior inspection prior to works start It is necessary to conduct DUT E S7 exterior inspection for the presence of the possible defects arisen during transportation storage or careless us...

Страница 21: ...Technoton 2021 21 2 2 Mounting Recommendations on installation length shortening and extension screen filter installation fastening and fixation of DUT E S7 are identical to the respective recommendations for wired DUT E sensors described in DUT E DUT E 2Bio DUT E GSM installation manual ...

Страница 22: ...1 BLE module activation WARNING The transfer of DUT E S7 indications to the Android device is possible only after activation of the sensor BLE module DUT E S7 has the following modes of operation determined by the status of its BLE module Storage the sensor is in this mode from the moment it is manufactured The BLE module of DUT E S7 is disabled no data transmission at all Manufacturing in this mo...

Страница 23: ...on 2021 23 Apply the magnetic key to the cover of the sensor head for 1 s a during the activation of the Manufacturing mode Bridge the tubes of the measuring probe Apply the magnetic key to the cover of the sensor head for 1 s b during the activation of the Operating mode Figure 9 Activation of DUT E S7 BLE module Area of magnetic key impact Area of magnetic key impact ...

Страница 24: ...enabling the Bluetooth of the Android device see figure 10 a and after the Bluetooth activation the window Searching aimed at detection of active DUT E S7 sensors is opened Each sensor detected is automatically entered into the list of accessible devices by the application Results area with displaying the following data see figure 10 b serial number 1 signal of the time the latest message was rece...

Страница 25: ...message from the sensor on the Android device should be displayed in Fuel Tank Monitor app see table 5 Table 5 Values of signals of time indicator of receiving last message from DUT E S7 Signal type Signal color Signal values Green Less than 20 s passed after receiving last message from the sensor Yellow 20 40 s passed after receiving last message from the sensor Orange 40 60 s passed after receiv...

Страница 26: ...lect operations with the sensor profile description of the selected menu item icon to open the Navigation menu monitoring of sensor indications configuration of notification of Events calibration of the measuring system tank calibration diagnostics of malfunctions etc and the Menu of settings selection of language of the interface and units of measurement Help button and displaying information of ...

Страница 27: ... need to find and select the profile file DUT E_S7_ prf7 is used to save the changed settings of the profile in the Android device memory is used for loading a profile with standard settings Figure 12 View of Profile menu Fuel Tank Monitor mobile application IMPORTANT All configuration changes made in Fuel Tank Monitor app are not stored in the sensor but in memory of Android device Configuration ...

Страница 28: ...memory of Android device in Sensor calibration bar of the Fuel Tank Monitor application Settings submenu Sensor tab see figure 13 Figure 13 Measuring system calibration with Fuel Tank Monitor application For the measuring system calibration make the following steps 1 Select the desired sensor from the list of available devices see 2 3 2 2 Get the sensor out of the fuel tank and wait for 30 60 seco...

Страница 29: ...of probe 5 Dip the probe s tubes fully into the fuel Wait for 10 20 seconds for sensor readings stabilization 6 To calibrate maximum highest point of level measurement press button in Sensor calibration bar 7 Save the changes of the profile in the memory of the Android device 8 Measuring system calibration is finished IMPORTANT If frequency values of the sensor measuring generator for the maximum ...

Страница 30: ...uel portions it is necessary to use measuring reservoir with inaccuracy not more than 0 25 To make fuel tank calibration correctly where the sensor is installed it is required to follow the procedure the Vehicle should not be loaded and stand on the flat horizontal surface fuel tank should be empty the vehicle wheels must be of standard size the tire pressure should match with the prescribed for t...

Страница 31: ...ng While creating the calibration table we recommend to enter for its first point level of 0 0 mm the value of the fuel volume which is equal to the volume of not consumed fuel remaining in the tank New entries are automatically sorted from low to high fuel level value If you need to cancel all changes press button To delete the line place the cursor into any of the cells and press button Button i...

Страница 32: ...tware calculates the volume of fuel in the Vehicle tank In order to transfer points of the generated calibration table from the Fuel Tank Monitor application to the Telematics server e g ORF 4 or Wialon perform the following operations see figure 16 In the settings of ORF 4 for the fuel level sensor New sensor window of the service Calculation Table tab enter all values from Frequency Hz column of...

Страница 33: ...e field Coefficient C To turn off the thermal compensation insert the coefficient value 0 0 or shift the blue slider to the left Thermal correction coefficient K ther corr is determined by formula 3 min min max min max ther corr V T T 100 V V 1 K 3 where Tmin and Tmax respectively the minimum and the maximum measured values of fuel temperature in the tank during 24 hours Vmin and Vmax measured val...

Страница 34: ...also used in the function of automatic defining the time left before the tank is filled during the fuelling operation It should be noted that this feature is active in any position of the blue slider contact in the Fuelling line To activate defining the low limit for the fuel left in the tank press sign in the line Low fuel level Move the blue slider contact to the right in the settings window tha...

Страница 35: ... Events Detection function in the Fuel Tank Monitor application Information windows appearing on the Android device display in case of Events see figure 19 are accompanied by sound and vibration signals For fuel tank Fuelling Discharging Event the following information is displayed see figure 19 a data and time of the Event occurrence volume of fill up drained fuel fuel volume in the beginning and...

Страница 36: ...s tab see figure 19 b Data on the latest Event and of the number of recorded Events are displayed in the Indicator panel submenu Data tab see figure 20 a a example of information windows of Events Fuelling Discharging b example of the list of recorded Events Figure 19 Display Events information in the Fuel Tank Monitor application IMPORTANT Enabling and correct operation of the feature of automati...

Страница 37: ...r can monitor in real time on the display of the Android device 1 Current values of Parameters fuel level in the tank fuel volume in the tank frequency of the sensor measuring generator fuel temperature in the tank remaining distance of the route depending on the average fuel consumption and the volume of fuel in the tank time left before the tank is filled during fuelling 2 Recorded Events Fuelli...

Страница 38: ...not limited Whenever you tick the Scroll field each added line of the Parameters will be displayed in the bottom portion of the table button serves to clear the list of all control points registered during logging The recorded log files are automatically placed into the installation folder of the application in the memory of the Android device Fuel Tank Monitor Log The log file name is generated a...

Страница 39: ... group from Searching area is performed by pressing button located to the right of the serial number of the respective sensor see figure 21 а By pressing button in the bottom portion of Multisensor group area you may add a sensor with any serial number entered by the user Using button you may delete any respective Slave sensor from the group However you cannot delete the Master sensor from the gro...

Страница 40: ...f a group of sensors Figure 21 Example of summation of readings of several DUT E S7 sensors in the Fuel Tank Monitor mobile application Buttons to add an accessible sensor to the group Button to delete sensors from the group Total indication of the fuel volume of the group of sensors Warning of active sensor malfunctions detected Button used to add a sensor with any serial number to the group Warn...

Страница 41: ...delivery set see figure 22 To seal the sensor put the sealing cord through the special holes of the mounting plate and DUT E S7 body Then put the ends of the cord through the holes in the center of the plastic seal body Latching the seal will lock the cord Seal removal will be impossible without its damaging Figure 22 Sealed DUT E S7 WARNING Sealing rope should not touch the fuel tank body Design ...

Страница 42: ...urement on the particular vehicle fuel tank The procedure of DUT E S7 accuracy check requires filling draining of the fuel tank and comparing sensor data with the actual amounts of filling draining Fuel drain is carried with manual or mechanical pump Calibrated measuring containers must be used to determine the exact amount of drained refilled fuel ATTENTION The amount of any fuel filling draining...

Страница 43: ...rained fuel with the calibrated measuring container 3 Record the data into the Check test report 4 Wait for the fuel getting still in the tank for stable DUT E S7 readings 5 Refuel the tank with the previously drained fuel 6 Record the data into the Check test report 7 When analyzing accuracy errors Drain and Refill Parameters are estimated as a percentage relative to the total tank capacity See a...

Страница 44: ...ea see figure 23 a You can also monitor the quality of the sensor performance 1 In the Searching window see 2 3 2 and in the Group tab Indicator panel submenu see 2 3 9 where the Self diagnostics Ok message is displayed under the serial number of each sensor in case no malfunctions are detected if there are some malfunctions Self diagnostics sign is displayed 2 In the Data tab Indicator panel subm...

Страница 45: ...nnually the correctness of the measuring system calibration for minimum and maximum levels of fuel in the tank provided that the tank has not lost its shape and was not replaced In case of incorrect indication repeat the measuring system calibration Re calibration of the fuel tank of Vehicle in this case is not required DUT E S7 repair works are carried out only by certified Regional Service Cente...

Страница 46: ...t the sealing cord carefully Unfasten DUT E S7 by turning its body counterclockwise Mount the fuel tank plug be ordered separately for protection from any possible clogging through mounting opening Remove screen filter and bottom stop from the end of measuring tubes ATTENTION 1 Screen filter dismantling should be done carefully to avoid breaking latches of fixator 2 In case of repeated installatio...

Страница 47: ...e following defects visible damages of the sensor head body measuring probe backlash of measuring unit tubes relative to each other and or the body presence of mud or paraffin between the tubes of the measuring probe damage of the plastic mounting plate and traces of fuel leaks through the rubber gasket of the mounting plate Contact RSC or Manufacturer if the defects detected ...

Страница 48: ...ing inside the inner measuring tube does not affect DUT E S7 normal operation Examine the space between two tubes of measuring part and between measuring part and additional electrode for mud and paraffin To clean the tubes wash them with the clean fuel If there is paraffin in the cavity between the tubes it is necessary to slightly warm the measuring part with a heat gun to remove it It is also r...

Страница 49: ...nks storage tanks in which DUT E S7 sensors are installed Figure 24 Exterior view of DUT E S7 Radiobox RS Application area DUT E S7 Radiobox RS may be used together with DUT E S7 wireless sensors as part of Telematics systems based on the Telematics terminal of any manufacturer that has RS 232 RS 485 input see figure 25 Figure 25 Example of DUT E S7 Radiobox RS employment in a transport Telematics...

Страница 50: ... manual Version 4 0 Technoton 2021 50 7 2 Delivery set 1 DUT E S7 Radiobox RS wireless interface 1 pc 2 Specification 1 pc 3 Mounting kit 1 pc including a fuse with holder 2 A 1 pc b cable tie 2 pcs c self adhesive clasp 5 cm 2 pcs Figure 26 DUT E S7 Radiobox RS delivery set 3 b 2 3 a 1 3 c ...

Страница 51: ...data and the non volatile memory to save user settings 2 wire bundle OUT designed for operational connection and service connection 3 S6 Mol service connector KLINE wire black for configuration VBAT orange and GND brown wires for power supply connection 4 TX blue and RX white wires for connection to the Telematics terminal via RS 232 interface 5 B blue and A white wires for connection to the Telem...

Страница 52: ... RS 485 Service interface K Line ISO 14230 Receiver sensitivity Rx dBm 88 Maximum distance to sensor m 20 in case there are metal partitions in the mounting location 50 when mounted within line of sight range Power supply voltage range V 9 45 Maximal current consumption at supply voltage 12 24 V mA not more than 80 60 Ambient operation temperature range C 40 85 Ingress protection rating IP40 Certi...

Страница 53: ...UT E COM protocol the data may be transmitted in the form of dimensionless units from 0 to 1000 0 empty tank 1000 full tank fuel level in the tank mm volume of fuel l volume of fuel related to the full tank Besides the data on the fuel level in the tank DUT E S7 Radiobox RS transmit data on the current fuel temperature The selection of the required data transmission mode and the user configuration...

Страница 54: ...ox RS wireless interface Technical specifications Overall dimensions DUT E S7 fuel level sensor Operation manual Version 4 0 Technoton 2021 54 7 4 3 Overall dimensions Figure 28 DUT E S7 Radiobox RS overall dimensions ...

Страница 55: ...n conditions of the Vehicle it is recommended that the distance between DUT E S7 Radiobox RS and DUT E S7 sensors should not exceed 20 m To fix DUT E S7 Radiobox RS make use of the self adhesive clasps that are contained in the delivery set DUT E S7 Radiobox RS is powered from the external source e g Vehicle onboard circuit The power supply service and output interfaces of DUT E S7 Radiobox RS are...

Страница 56: ...ector Pinout Connector Contact Number Wire Marking Wire Color Circuit Designation Signal Parameters S6 Mol 1 VBAT Orange Power Analog voltage 9 45 V 2 GND Brown Ground 5 KLIN Black K Line Digital ISO 14230 Standard TX Blue Data transmitted Digital RS 232 Standard RX White Data received B Blue Exchange of data Digital RS 485 Standard A White Exchange of data Manufacturer reserves the right to modif...

Страница 57: ...mmunication faults between DUT E S7 Radiobox RS and PC make sure there are no sources of electromagnetic interference close to the workplace running electric motors welding equipment high power transformers power lines etc Before starting with service adapter it is necessary to download software from https www jv technoton com section Software Firmware and install it to PC USB driver Service S6 DU...

Страница 58: ...S and the PC The software will search for devices connected to the PC and will display the Connection window containing the list of Units accessible for connection Besides DUT E S7 Radiobox RS accessible DUT E S7 wireless sensors up to 2 pcs may be displayed in the list The profile of each of these sensors can be loaded separately and configured for operation together with DUT E S7 Radiobox RS see...

Страница 59: ...a output Auto ASCII EXT extended text format of the automatic data output In case it is used fields of additional parameters are available for editing Text Message Prefix and Text Message Suffix which respectively establish the beginning and the end of the transmitted data in the text format 32 characters at a maximum In the field Sending Interval s you can set the value of the time interval for w...

Страница 60: ...and 102 for its identification In the appearing window Add Unit its serial number and network address are displayed for the sensor added see figure 33 b For each sensor added to the Allowed Units S7 List the possibility of operation using S7 Technology is determined in accordance with its accessibility status Enable Disable WARNINGS 1 After adding the sensor into the Allowed Units S7 List you must...

Страница 61: ...tion of fuel volume readings the profile of each of the DUT E S7 sensors operating together with DUT E S7 Radiobox RS must contain the calibration parameters Empty and Full frequencies as well as the calibration table of the respective tank The procedures of calibration and creation of calibration tables are carried out using Service S6 DUT E software similar to the respective procedures for cable...

Страница 62: ...ally enter values of calibration points into the memory of DUT E S7 Radiobox RS in the submenu of the FM Fuel level sensor see D 2 Calibration Table tab e g using readings of the Android device see 2 3 6 or load them from the file ttr Save the modified profiles of the DUT E S7 sensors Figure 35 The procedure of editing manually calibration frequencies of DUT E S7 wireless sensor 1 Tick 2 Press but...

Страница 63: ...ng shape see figure 36 Figure 36 DUT E S7 packaging Label sticker with information on the product name serial number firmware version manufacture date weight as well as Quality Control seal and QR code is stuck on two sides of the DUT E S7 box see figure 37 Figure 37 DUT E S7 packaging label Note Label design and contents can be modified by the Manufacturer ...

Страница 64: ...red in dry enclosed areas DUT E S7 storage is allowed only in original packaging at temperature range from 10 to 30 C and relative humidity from 45 to 75 at 25 C Do not store DUT E S7 in the same room with substances that cause metal corrosion and or contain aggressive impurities DUT E S7 shelf life must not exceed 24 months ...

Страница 65: ...osed transport that provides protection for DUT E S7 from mechanical damage and precipitation When transporting by air DUT E S7 must be stored in heated pressurized compartments Air environment in transportation compartments should not contain acid alkaline and other aggressive impurities Shipping containers with packed DUT E S7 sensors should be sealed ...

Страница 66: ...contains harmful substances and components that are hazardous to human health and environment Battery must not be disposed of together with general domestic waste The Buyer is responsible for the disposal of battery by means of its delivery to the hazardous waste collecting center this will ensure safety for human health and environment Technoton bears no responsibility for any non compliance with...

Страница 67: ...al Version 4 0 Technoton 2021 67 Contacts Distribution technical support and service Tel Fax 375 17 240 39 73 https www jv technoton com marketing technoton by support technoton by Manufacturer Zavod Flometr Tel fax 375 1771 3 29 21 office flowmeter by ...

Страница 68: ...tank volume 100 V V V M Android me total_volu Refueling volume According to calibrated container M V liters According to the indication on the display of the Android device Android V liters Accuracy error Absolute error M Android V V liters Normalized to total tank volume 100 V V V M Android me total_volu Resume The results of drain measurement match do not match specifications The results of refu...

Страница 69: ...ee that interference will not occur in a particular installation If BLE module creates harmful interference to the reception of radio or television signals what can be determined by turning BLE module on and off it is recommend for a user to try to eliminate the interference in one or more of the following ways change the direction or location of the receiving antenna increase the distance between...

Страница 70: ... T4 X Where X means that when installing and operating the sensor special actions should be carried out to avoid occurrence of sparks caused by hits and frictions Ex marking is placed on measuring head of the sensors as pictured on figure C 1 Figure C 1 Placing of Ex mark on DUT E S7 3 DUT E S7 application area in hazardous locations of classes 0 1 and 2 according to IEC 60079 10 1 2006 GOST IEC 6...

Страница 71: ... D 1 Example of the window of settings of FM Self diagnostics in Service S6 DUT E software Table D 1 Self diagnostics FM Displayed and or editable SPN with the help of Service S6 DUT E software SPN Name Factory value Unit of measure Clarification Unit Passport PGN 62995 521120 Serial number On the fact No Serial number is a set of numbers that is used for identification of specific Unit Serial num...

Страница 72: ... of Unit restarts On the fact pcs Counter of Unit s processor restarts at a time when the power is On or there is an impact of conducted interferences of the vehicle s on board network Restarts accounting is carried out since production date of the Unit The user cannot reset the value of this counter It can be reset by the Manufacturer or RSC only Unit Passwords PGN 63017 521593 3 3 Password 3 3 I...

Страница 73: ...ce S6 DUT E software for the profile of DUT E S7 wireless sensor operating together with DUT E S7 Radiobox RS Table D 2 Fuel level sensor FM Displayed and or editable SPN with the help of Service S6 DUT E software SPN Name Factory value Unit of measure Range Clarification Calibration parameters PGN 63076 521440 22 0 Duty cycle 22 0 Empty On the fact 0 4294970 This setting displays duty cycle of si...

Страница 74: ...4 Fuel temperature 1 On the fact C 40 210 This setting displays present value of fuel temperature in the vehicle s tank Instrumental display PGN 65276 96 Fuel level 1 On the fact 0 100 This setting displays value in of present fuel level in the tank in relation to the level of full Vehicle s tank Settings of FM Level sensor PGN 63029 521433 Temperature correction coefficient 0 084 C 32 32 Field fo...

Страница 75: ...Service S6 DUT E software SPN Name Factory value Unit of measure Range Clarification Total fuel volume in tanks PGN 63152 521024 2 11 Fuel Tank Volume 2 11 Summary Value On the fact l 0 6425 5 Displays the value of total fuel volume in tanks selected for summation Summation settings PGN 63149 521259 27 0 Fuel Level Sensor Summation Enable 27 0 DUT 1 Off On Off A field for turning on off summation ...

Страница 76: ...oring of onboard power network voltage current mode of power network operation time of Vehicle in different power network modes quantity of engine starts exceeding permissible time of continuous operation of starter Preparation for release Figure D 4 Operation modes on onboard network ON voltage level Figure D 5 Example of the window of settings of Vehicle power supply FM in Service S6 DUT E softw...

Страница 77: ... see figures D 4 and D 5 521065 Engine Starter Voltage Level 0 91 0 1 99 Field for entering value of voltage level starter is running i i when Vehicle s engine is starting 0 91 Unom see figures D 4 and D 5 521067 Low Voltage Level 0 75 0 1 99 Field for entering value of low voltage level of ON 0 75 Unom Entered value of voltage is used as a threshold for recording Faulty ON Event see figures D 4 a...

Страница 78: ...setting displays the unique identifier MAC address of BLE module of the wireless Unit Using MAC address the software generates a serial number of a specific Unit and also identifies its accessibility status for operation based on S7 Technology The data are not accessible for editing 521178 Received Signal Strength Indicator RSSI On the fact dBm The setting displays the current level of the signal ...

Страница 79: ...e work using S7 Technology The value of the network address 101 or 102 is automatically assigned to DUT E S7 fuel level sensor by its ordinal number Network addresses of DUT E S7 cannot be modified by the user 521490 MAC Address On the fact No Sensor MAC address itself of DUT E S7 sensor selected by the user for connection by means of S7 Technology is not displayed in the list of authorized Units ...

Страница 80: ...the software will send warning message To cancel firmware upgrade it is needed to press button ATTENTION Before the end of the update process and automatic Service S6 DUT E software reset it is forbidden power down the PC power down the DUT E S7 Radiobox RS disconnect DUT E S7 Radiobox RS from the adapter and adapter from the PC run any resource intensive applications on the PC Service S6 DUT E so...

Страница 81: ...N7o 4 Animation DUT E GSM fuel level sensor Check out the link https www youtube com watch v ixBaKMzKtG8 5 Video clip DUT E 485 fuel level sensor installation Check out the link https www youtube com watch v X0gUSF3dRWk 6 Video clip Length extension of measurement part DUT E Using measuring sections KDC Check out the link https www youtube com watch v dWuY_JJfhFw 7 Video clip Filter Screen of DUT ...

Отзывы: