DUT-E S7 installation / Wireless transfer of sensor indications to the Android device / Adaptation of indications for specific conditions of exploitation
DUT-E S7 fuel level sensor. Operation manual. Version 4.0
©
Technoton, 2021
34
Figure 17
—
Configuration of Thermal Correction and Remaining Distance functions
in the Fuel Tank Monitor application
3)
Detection of Events
function (
Settings
submenu,
Events
tab) is used for automatic
and the user notification of their occurrence. By default, this function is
OFF for all Events. To detect Events, there are the following settings (see figure
18):
•
To activate the detection of the
“
Discharging
”
Event, press
in the
Discharging
line.
Move the blue slider contact to the right in the settings window that opens. In the field
Threshold, l/h
enter the threshold value of the fuel consumption. In case this value is
exceeded, the application will display information of the respective Event.
•
To activate the detection of the
“
Fuelling
”
Event, press
in the
Fuelling
line. Move
the blue slider contact to the right in the settings window that opens. In the field
Threshold, l/h
enter the threshold value of the fuel consumption. In case this value is
exceeded, the application will display information of the respective Event.
Note
—
The specified threshold value of the fuel consumption is also used in the
function of
automatic defining the time left before the tank is filled, during the
fuelling operation
. It should be noted that this feature is active in any position of the
blue slider contact in the
Fuelling
line.
•
To activate defining the low limit for the fuel left in the tank, press
sign in the line
Low fuel level
. Move the blue slider contact to the right in the settings window that
opens. In the field
Threshold, l
enter the value of the minimum volume of fuel in the
tank below which the application will display information of the respective Event.
•
To activate defining the minimal fuel temperature at which the engine can be started,
press
sign in
Low
temperature
line. Move the blue slider contact to the right in the
settings window that opens. In the field
Threshold
, °
C
enter the value of the minimum
temperature of fuel in the tank, below which the application will display information of
the respective Event.
•
To activate defining the maximal fuel temperature at which the engine can be started,
press
sign in
Hight temperature
line. Move the blue slider contact to the right in
the settings window that opens. In the field
Threshold
, °
C
enter the value of the
maximum temperature of fuel in the tank above which the application will display
information of the respective Even.
Icon to enter the window of
the thermal correction
configuration
Field to enter the average
fuel consumption
Field to enter the
thermal correction
coefficient
Slider contact to
activate/disable the thermal
correction function