iMOT Intelligent Motors Line Technical Reference
3.13.8 Analog 0…5V Input (ANLG)
Min.
Typ.
Max.
Units
Input voltage
Operational range
0
5
V
Absolute maximum values, continuous
-8
+12
Absolute maximum, surge (duration
≤
1s)
†
±24
Input impedance
To GND
33
kΩ
Resolution
12
bits
Integral linearity
±2
bits
Offset error
±2
±10
bits
Gain error
±1%
±3%
% FS
Bandwidth (-3dB)
Software selectable
0
250
kHz
ESD protection
Human body model
±5
kV
3.13.9 RS-232
Min.
Typ.
Max.
Units
Standards compliance
TIA/EIA-232-C
Bit rate
Depending on software settings
9600
115200 Baud
Short-circuit protection
232TX short to GND
Guaranteed
ESD protection
Human body model
±15
kV
3.13.10 EARTH Connection
Min.
Typ.
Max.
Units
EARTH to GND
Galvanic isolation
-100
+100
V
DC
Capacitive coupling
200
nF
Discharge resistor
300
kΩ
EARTH connection
Location
Front plate of motor, using 4x M3x4
threaded holes
Connection
Required for EMC compliance and
thermal dissipation
3.13.11 CAN-Bus (for CAN motors)
Min.
Typ.
Max.
Units
Compliance
ISO11898, CiA-301v4.2, 402v3.0
Bit rate
Software selectable
125
1000
Kbps
Bus length
1Mbps
25
m
500Kbps
100
≤ 250Kbps
250
Resistor
Between CAN-Hi, CAN-Lo
none on-board
Node addressing
Hardware: by H/W means (where SW1 is available)
1 - 15 & 127 (CANopen);
1 - 15 & 255 (TMLCAN)
Software
1 ÷ 127 (CANopen); 1- 255 (TMLCAN)
ESD protection
Human body model
±15
kV
3.13.12 EtherCAT (for CAT motors)
Min.
Typ.
Max.
Units
Compliance
IEEE802.3, IEC61158
Transmission line specification
According to TIA/EIA-568-5-A
Cat. 5e.UTP
J1, J2 pinout
EtherCAT® supports MDI/MDI-X auto-crossover
TIA/EIA-568-A or TIA/EIA-568-B
Software protocols compatibility
CoE, CiA402, IEC61800-7-301
Node addressing
Software set in setup
Value of Axis ID set by
software in Drive
Setup
1 ÷ 254
255
Value of “Configured
Station Alias” register
1 ÷ 254
0
MAC addressing
none
ESD protection
Human body model
±15
kV
†
Stresses beyond values listed under “absolute maximum ratings” may cause permanent damage to the device. Exposure to absolute-maximum-rated
conditions for extended periods may affect device reliability.
1
“FS” stands for “Full Scale”