12 TECHNICAL SPECIFICATIONS 

 

ITEM 

SPECIFICATION 

Rated operating distance 

0,5m … 6,0m K2C model 
0,5m … 5,0m K3C and K4C model 

Emitted light source 

Infrared LED (880 nm) 

Ambient light immunity  

According to IEC61496-2 

beam pitch (center) 

F3S-TGR-SBx-K2C-500 

Æ

 500mm 

F3S-TGR-SBx-K3C-800 

Æ

 400mm 

F3S-TGR-SBx-K4C-900 

Æ

 300mm 

number of beams 

F3S-TGR-SBx-K2C-500 

Æ

 2 

F3S-TGR-SBx-K3C-800 

Æ

 3 

F3S-TGR-SBx-K4C-900 

Æ

 4 

protective height 

F3S-TGR-SBx-K2C-500 

Æ

 516 

F3S-TGR-SBx-K3C-800 

Æ

 816 

F3S-TGR-SBx-K4C-900 

Æ

 916 

EAA 

According to IEC 61496-2 

Indicators 

2 green LEDS 
2 yellow LEDS 
1 red LED 

Dimensions (width x depth) 
 
Length 

Profile: 35*45mm  
            +2mm for connector part 
F3S-TGR-SBx-K2C-500: 595 mm 
F3S-TGR-SBx-K3C-800: 941 mm 
F3S-TGR-SBx-K4C-900: 1041 mm 

F3S-TGR-SBx-KxC series User’s 

manual 

 

 32

 

ITEM 

SPECIFICATION 

Materials 
Housing 
Front panel 
Sealing gasket 
Connector parts 

 
Powder-coated aluminum,  
Polycarbonate 
EPDM (synthesis rubber) 
Metal: Galvanized brass 
Plastic: PVC 

Housing color 

Yellow, RAL 1023 

Connection  

M12 connector, 8-pole  

Operation temperature range  

- 10 °C ... + 55 °C 

Storage temperature range  

- 25 °C ... + 70 °C 

Relative humidity  

15 % ... 95 % RH (no condensing) 

Enclosure rating (EN 60529)  

IP 65 

Pollution degree 

II 

Installation category 

II  process control equipment 

Altitude 

Up to 2000m 

External controls 

Test/Restart Muting and override 

Resistance to 
Vibration (to IEC 68-2-6) 
Shock (to IEC 68-2-27) 

10 – 70 Hz 

±

 1.5mm amplitude, X, Y, 

Z directions 
30G, 16ms, X, Y, Z direction 

Rated operating voltage 

+ 24 V DC, polarized 

Operating voltage range 

+19.2 … 28.8Vdc 

Current consumption 

< 420mA (muting lamp included) 

Power-on delay  

< 800ms 

Outputs PNP 

 

Содержание F3S-TGR-SB-K2C-500 Series

Страница 1: ...o it whenever necessary Do not open the housing or make any unauthorised modifications The power supply must be disconnected before proceeding with any external intervention Regulations and Standards...

Страница 2: ...with any standards codes or regulations that apply to the combination of products in the customer s application or use of the product At the customer s request TECHNO GR will provide applicable third...

Страница 3: ...2 2 2006 F3S TGR SBx KxC series User s manual 6 INDEX section page 1 OPERATION 7 2 PRECAUTIONS AND CRITERIA FOR INSTALLATION 8 2 1 CALCULATION OF THE MINIMUM DISTANCE FOR INSTALLATION 8 2 2 REFLECTING...

Страница 4: ...ator must be connected when the SLC is not connected to the power supply as shown in section 6 and then the SLC s power supply must be restored To disable the muting function the LMS muting indicator...

Страница 5: ...nearby surfaces Serious injuries can result if these effects are not taken into consideration Should there be any reflecting surfaces the distance must be sufficient to safeguard against passive refl...

Страница 6: ...n the opposite directions Staggered SLC1 Mirror2 SLC1 Mirror1 Mirror2 SLC2 Mirror1 SLC2 All these installation will prevent mutual interference between SLC F3S TGR SBx KxC series User s manual 12 Inse...

Страница 7: ...ves so the brackets d can be placed at an equal distance from each other Fixing facilities list 1 Movable nuts 8pcs 2 Fixing brackets 4pcs 3 Washer 8pcs 4 Grower 8pcs 5 Nut 8pcs F3S TGR SBx KxC series...

Страница 8: ...ety relay module Muting input A and Muting input B can be provided by mechanical switch photoelectric sensors proximities switch with closed contact in the presence of the object to be detected The te...

Страница 9: ...override the system and they should therefore be used with due care 7 2 MUTING FUNCTION As mentioned in the introduction the muting function can be enabled with any SLC by simply connecting the LMS m...

Страница 10: ...ng 1 Wiring must be done correctly 2 The muting sensors must recognise the whole length of the material i e pallets vehicles 3 The sensors must be arranged so that the material is also recognised if i...

Страница 11: ...Yellow 4 Muting input A Green 3 Input of A1 sensor Input of A2 sensor Input of B1 sensor Input of B2 sensor 24Vdc D a n g e r o u s z o n e F3S TGR SBx KxC series User s manual 22 Application with fo...

Страница 12: ...imum dimension of package that can cross the SLC D1 distance between muting actuator B and SLC It MUST be as short as possible Minimum distance allowable depends on the speed of conveyour the response...

Страница 13: ...time as long as the muting signals are valid Timing chart F ree Interrupted O N O F F O N O F F O N O F F A ctive O F F S LC O S S D M uting Input A M uting Input B M uting S tatus 0 03 sec Tm 3sec A...

Страница 14: ...5 seconds The override function is now enabled The LMS muting indicator flashes to signal the exclusion of the SLC The maximum duration of the override function is 120 seconds after which the SLC is r...

Страница 15: ...1 and 4 2 Check that it is not possible for a person to get between the SLC and the dangerous parts of the machinery Check that there is no external damage to the SLC and or to the external electrical...

Страница 16: ...SBx K3C 800 941 mm F3S TGR SBx K4C 900 1041 mm F3S TGR SBx KxC series User s manual 32 ITEM SPECIFICATION Materials Housing Front panel Sealing gasket Connector parts Powder coated aluminum Polycarbo...

Страница 17: ...Reverse polarity Overload Short circuit pulsed Input circuit Logical Zero level 0 8V Logical One level 14 24Vdc Input pulse duration Min 2 cycle time Response time 16ms Reset time TOFF TON interlock 3...

Страница 18: ...xC series User s manual 35 MODEL A B C D E L F3S TGR SBx K2C 500 500 514 614 F3S TGR SBx K3C 800 118 400 60 340 814 958 F3S TGR SBx K4C 900 118 300 300 300 914 1058 F3S TGR SBx KxC series User s manua...

Отзывы: