The TEST/RESTART button must be located so that the operator can 
see the protected area when restarting

testing or overriding. 

• 

The external illuminated indicator for 

muting override 

enabled must 

be located so that it can be seen from all sides of operation. 

• 

If the 

muting

 sensors are installed very close to the SLC, care must 

be taken that the receivers of the sensors are mounted on the 
mirror side of the SLC in order to avoid interference. 

• 

The system is protected against the possibility of faults due to 
damage to the wires; however we recommend laying the cables for 
all connections in order to avoid damage to the connection cables. 

 

7.5 

TIMING CONSTRAINTS (muting function) 

 

a) The 

muting

 request must take place with the correct timing 

sequence: the Muting A input must be enabled first and then the 
Muting B input. The request for the latter must be made within a 
maximum of 3 seconds and not before 30 ms (TM) after enabling  
Muting A input. Otherwise the 

muting

 function will not be enabled. 

An incorrect sequence on the 

muting

 inputs will not start the muting 

process. 

b) 

Muting

 status can be maintained for an unlimited period of time as 

long as the muting signals are valid. 

 
Timing chart

     

       

      

 

F re e

In te rru p te d

O N

O F F

O N

O F F

O N

O F F

A c tiv e

O F F

S L C  
 
 
 
O S S D  
 
 
 
M u tin g    
          In p u t  A  
 
 
M u tin g    
          In p u t  B  
 
 
M u tin g      
     S ta tu s  

0 .0 3   s e c   <   T m <   3 s e c  

 

 

muting

 request cannot be made if the SLC outputs are open, that 

is to say when the beams have been interrupted. 

F3S-TGR-SBx-KxC series User’s 

manual 

 

 26

 

7.6 

Timing constraints (for SLCs with postfix “–MTL” at the ordering 
code) 

 

a) The 

muting

 request must take place with the correct timing 

sequence: the Muting A input must be enabled first and then 
the Muting B input. The request for the latter must be made 
within a maximum of 3 seconds and not before 30 ms after the 
enabling of the Muting A input. Otherwise the 

muting

 function 

will not be enabled. An incorrect sequence on the 

muting

 inputs 

will not start the muting process. 

b)  There are 5 seconds maximum from the activation of muting to 

the package entrance in the protected area by interrupting the 
SLC. If this time is exceeded, muting function will stop 
immediately. 

c)  As long as a package interrupts the protected area (at least one 

beam), the muting function is maintained 

d) 

Muting

 status can be maintained for an unlimited period of time 

as long as the muting signals are valid. 

 

Timing chart 

 

                  

 

Free

Interrupted

ON

OFF

ON

OFF

ON

OFF

Active

OFF

SLC 
 
 
 
OSSD 
 
 
 
Muting  
     Input A 
 
 
Muting  
     Input B 
 
 
Muting   
     Status 

Ts< 5 sec

0.03 sec < Tm < 3sec 

 

 

 

Содержание F3S-TGR-SB-K2C-500 Series

Страница 1: ...o it whenever necessary Do not open the housing or make any unauthorised modifications The power supply must be disconnected before proceeding with any external intervention Regulations and Standards...

Страница 2: ...with any standards codes or regulations that apply to the combination of products in the customer s application or use of the product At the customer s request TECHNO GR will provide applicable third...

Страница 3: ...2 2 2006 F3S TGR SBx KxC series User s manual 6 INDEX section page 1 OPERATION 7 2 PRECAUTIONS AND CRITERIA FOR INSTALLATION 8 2 1 CALCULATION OF THE MINIMUM DISTANCE FOR INSTALLATION 8 2 2 REFLECTING...

Страница 4: ...ator must be connected when the SLC is not connected to the power supply as shown in section 6 and then the SLC s power supply must be restored To disable the muting function the LMS muting indicator...

Страница 5: ...nearby surfaces Serious injuries can result if these effects are not taken into consideration Should there be any reflecting surfaces the distance must be sufficient to safeguard against passive refl...

Страница 6: ...n the opposite directions Staggered SLC1 Mirror2 SLC1 Mirror1 Mirror2 SLC2 Mirror1 SLC2 All these installation will prevent mutual interference between SLC F3S TGR SBx KxC series User s manual 12 Inse...

Страница 7: ...ves so the brackets d can be placed at an equal distance from each other Fixing facilities list 1 Movable nuts 8pcs 2 Fixing brackets 4pcs 3 Washer 8pcs 4 Grower 8pcs 5 Nut 8pcs F3S TGR SBx KxC series...

Страница 8: ...ety relay module Muting input A and Muting input B can be provided by mechanical switch photoelectric sensors proximities switch with closed contact in the presence of the object to be detected The te...

Страница 9: ...override the system and they should therefore be used with due care 7 2 MUTING FUNCTION As mentioned in the introduction the muting function can be enabled with any SLC by simply connecting the LMS m...

Страница 10: ...ng 1 Wiring must be done correctly 2 The muting sensors must recognise the whole length of the material i e pallets vehicles 3 The sensors must be arranged so that the material is also recognised if i...

Страница 11: ...Yellow 4 Muting input A Green 3 Input of A1 sensor Input of A2 sensor Input of B1 sensor Input of B2 sensor 24Vdc D a n g e r o u s z o n e F3S TGR SBx KxC series User s manual 22 Application with fo...

Страница 12: ...imum dimension of package that can cross the SLC D1 distance between muting actuator B and SLC It MUST be as short as possible Minimum distance allowable depends on the speed of conveyour the response...

Страница 13: ...time as long as the muting signals are valid Timing chart F ree Interrupted O N O F F O N O F F O N O F F A ctive O F F S LC O S S D M uting Input A M uting Input B M uting S tatus 0 03 sec Tm 3sec A...

Страница 14: ...5 seconds The override function is now enabled The LMS muting indicator flashes to signal the exclusion of the SLC The maximum duration of the override function is 120 seconds after which the SLC is r...

Страница 15: ...1 and 4 2 Check that it is not possible for a person to get between the SLC and the dangerous parts of the machinery Check that there is no external damage to the SLC and or to the external electrical...

Страница 16: ...SBx K3C 800 941 mm F3S TGR SBx K4C 900 1041 mm F3S TGR SBx KxC series User s manual 32 ITEM SPECIFICATION Materials Housing Front panel Sealing gasket Connector parts Powder coated aluminum Polycarbo...

Страница 17: ...Reverse polarity Overload Short circuit pulsed Input circuit Logical Zero level 0 8V Logical One level 14 24Vdc Input pulse duration Min 2 cycle time Response time 16ms Reset time TOFF TON interlock 3...

Страница 18: ...xC series User s manual 35 MODEL A B C D E L F3S TGR SBx K2C 500 500 514 614 F3S TGR SBx K3C 800 118 400 60 340 814 958 F3S TGR SBx K4C 900 118 300 300 300 914 1058 F3S TGR SBx KxC series User s manua...