background image

4

EG

SAFETY INSTRUCTIoNS

l

 

Read this booklet carefully before using this air 

conditioner. If you still have any difficulties or 

problems, consult your dealer for help.

l

 

This  air  conditioner  is  designed  to  give  you 

comfortable room conditions. Use this only for its 

intended purpose as described in this Instruction 

Manual.

l

 

Never use or store gasoline or other flammable vapor or 

liquid near the air conditioner. It is very dangerous.

l

 

Never install electrical equipment, which is not 

protected with IPX1 protection (protection against 

vertical water drop), under the unit.

l

 

The manufacturer assumes no responsabilities if the 

safety regulations or local codes are not observed.

l

 

Never use the power main switch to start or stop the 

air conditioner: always use the oN/oFF button on the 

remote control unit or the selector switch on the unit.

l

 

Do not let children play with the air conditioner.

l

 

Do not cool the room too much if babies or invalids 

are present.

l

 

This air conditioner is not intended for use by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision 

or instruction concerning use of the air conditioner 

by a person responsible for their safety.

WARNING

CAUTIoN

INSTALLATIoN LoCATIoN

l

 

We recommend this air conditioner to be installed 

properly by qualified installation technicians in 

accordance with the installation instructions 

provided with the unit.

l

 

Do not install this air conditioner where there are 

fumes or flammable gases, or in an extremely humid 

space such as a green house.

l

 

Do not install the air conditioner where excessively 

high heat-generating objects are placed.

l

 

Do not install the air conditioner where the 

atmosphere  is  extremely  damp  or  humid  (e.g. 

greenhouse or laundry) it could be wetted by drops 

of water (i.e. in laundries).

l

 

To protect the air conditioner from heavy corrosion, 

avoid installing the outdoor unit where  salty sea 

water can splash directly onto it or in sulphurous 

air near a spa.

WARNING

ELETRICAL REQUIREMENTS

l

 

Before installation, check that the voltage of the electric 

supply in your home or office is the same as the voltage 

shown on the nameplate.

All wiring must conform to the local electrical codes. 

Consult your dealer or a qualified electrician for details.

l

 

Each unit must be properly grounded with a ground (or 

earth) wire or through the supply wiring.

l

 

Wiring must be done by a qualified electrician.

hoW To INSTALL BATTERIES

l

  Remove trhe lid in the rear part of the remote control 

unit and check the settings of the four microswitches 
as shown below:

TEMPERATURE SENSOR SELECTOR 

l

 

Under normal conditions the room temperature is 

detected and checked by the temperature sensor placed 

in the remote controller (I FEEL icon displayed ).This 

function is designed to provide a comfortable room 

temperature by transmitting the temperature control 

command from the location next to you. When using this 

function, the remote, control should always be pointed 

at the air conditioner, therefore it should be placed in 

a position in which it is visible by the indoor unit (for 

example, do not put it in a drawer).

l

 It is possible to disable the remote controller room 

sensor pressing the I FEEL button. In this case the I 

FEEL icon on the remote controller display lights off and 

only the sensor placed in the air conditioner becomes 

active.

USING THE REMOTE CONTROL UNIT

l

  Insert two AAA alkaline batteries of 1,5 V-DC making 

sure that point in the direction marked in the battery 

compartment.The displayed time flashes.

  Press the SEL TYPE button.

  Remote controller is now ready for operation. 

l

  The batteries last average more than six months, 

anyway it depends on how much you use the remote 

control unit.

  Remove the batteries if you do not use the remote 

control unit for more than one month.

  Replace the batteries when  the remote control unit 

lamp fails to light, or when the air conditioner does not 

receive the remote control unit signals.

l

  The batteries of the remote control contain polluted 

substances. Exhausted batteries must be disposed 

according to the laws in force.

OPERATION WITH THE REMOTE CONTROL UNIT

When using the remote control unit, always point the unit 
transmitter head directly at the air conditioner receiver.

hoW To TURN oN ThE AIR CoNDITIoNER

Press the ON/OFF button to turn the air conditioner on. 
The operation lamp will light up, indicating the unit is in 
operation.

The  remote  control  unit  transmits  signals  to  the 

indoor unit each time you press a key and at any 

temperature change detected by the IFEEL sensor. In 

case of troubles (low batteries, remote control placed 

in a position not visible by the indoor unit,...) room  

temperature control  is automatically switched to the 

sensor of the indoor unit. In this case, the temperature 

around the remote control unit may differ from the 

temperature detected in the air conditioner position.

NoTE

SWITCHES

NoTE

IF YOU INSTALL MORE THAN ONE INDOOR 
UNIT IN THE SAME ROOM:

It is possible to utilise only one remote control for all 
the units.
on the contrary, if you want to address each remote 
control to its unit, follow the procedure”Remote control 
unit/indoor unit address” (see Installation Instructions).

PLEASE, SEE THE END 
OF THIS MANUAL FOR 

DETAILS

Содержание DSA10FICR5IBA

Страница 1: ...A NOTICE D UTILISATION OPERATING INSTRUCTIONS ISTRUZIONI D USO INSTRUCCIONES DE USO BEDIENUNGSANLEITUNG Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimage...

Страница 2: ...UBLESHOOTING 10 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 14 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will need the following...

Страница 3: ...WARNING EG NAME OF PARTS AND OPERATION SELECTOR switch 5 6 7 8 9 3 10 11 2 1 4 NOTA When the unit receives a signal from the remote controller all the three lamps OPERATION TIMER and STANDBY light up...

Страница 4: ...he remote control unit and check the settings of the four microswitches as shown below TEMPERATURE SENSOR SELECTOR l Under normal conditions the room temperature is detected and checked by the tempera...

Страница 5: ...THE TIMER IFEEL IFEEL C SENSOR SELECTOR Press this button to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan...

Страница 6: ...SHOW THE ROOM TEMPERATURE AGAIN 3 Press the FAN selector button to the setting you want During Automatic Operation IFEEL ON the set temperature is understood as perceived one then the system is automa...

Страница 7: ...es the operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating...

Страница 8: ...utton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit...

Страница 9: ...has troubles follow the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode COOL or HEAT OPE...

Страница 10: ...ble the air conditioner does not run at all Possible cause 1 Power failure 2 Leakage breaker tripped 3 Operation button is OFF 4 Batteries in remote control unit have run down Remedy 1 Restore power 2...

Страница 11: ...and flap is closed The system restarts automatically as soon as the problem on the out door unit is solved Check the error code using the appro priate LEDs on the PCB of the outdoor unit Follow the in...

Страница 12: ...ck that the dip switch SW2 for communication address setting is in the correct position Check that all earth cables are properly connected to every terminal C h e c k t h a t t h e s h i e l d o f t h...

Страница 13: ...cal wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Chec...

Страница 14: ...providing this service Disposing of a battery separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to be...

Страница 15: ...Z I Route d partementale 28 01600 Reyrieux France T l 33 4 74 00 92 92 Fax 33 4 74 00 42 00 Technibel is a trademark of NIBE ENERGY SYSTEM FRANCE...

Отзывы: