background image

EG

I

F

D

E

37.4254.078.00    11/2015

DSA14FIBR5IBA
DSA10FICR5IBA

NOTICE D’UTILISATION • OPERATING INSTRUCTIONS

ISTRUZIONI D’USO • INSTRUCCIONES DE USO

BEDIENUNGSANLEITUNG

Split air conditioner system • Condizionatore d’aria split system

Climatiseurs split • Split-klimagerät

Acondicionador de aire de consola partida sistema split

Содержание DSA10FICR5IBA

Страница 1: ...A NOTICE D UTILISATION OPERATING INSTRUCTIONS ISTRUZIONI D USO INSTRUCCIONES DE USO BEDIENUNGSANLEITUNG Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimage...

Страница 2: ...UBLESHOOTING 10 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 14 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will need the following...

Страница 3: ...WARNING EG NAME OF PARTS AND OPERATION SELECTOR switch 5 6 7 8 9 3 10 11 2 1 4 NOTA When the unit receives a signal from the remote controller all the three lamps OPERATION TIMER and STANDBY light up...

Страница 4: ...he remote control unit and check the settings of the four microswitches as shown below TEMPERATURE SENSOR SELECTOR l Under normal conditions the room temperature is detected and checked by the tempera...

Страница 5: ...THE TIMER IFEEL IFEEL C SENSOR SELECTOR Press this button to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan...

Страница 6: ...SHOW THE ROOM TEMPERATURE AGAIN 3 Press the FAN selector button to the setting you want During Automatic Operation IFEEL ON the set temperature is understood as perceived one then the system is automa...

Страница 7: ...es the operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating...

Страница 8: ...utton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit...

Страница 9: ...has troubles follow the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode COOL or HEAT OPE...

Страница 10: ...ble the air conditioner does not run at all Possible cause 1 Power failure 2 Leakage breaker tripped 3 Operation button is OFF 4 Batteries in remote control unit have run down Remedy 1 Restore power 2...

Страница 11: ...and flap is closed The system restarts automatically as soon as the problem on the out door unit is solved Check the error code using the appro priate LEDs on the PCB of the outdoor unit Follow the in...

Страница 12: ...ck that the dip switch SW2 for communication address setting is in the correct position Check that all earth cables are properly connected to every terminal C h e c k t h a t t h e s h i e l d o f t h...

Страница 13: ...cal wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Chec...

Страница 14: ...providing this service Disposing of a battery separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to be...

Страница 15: ...Z I Route d partementale 28 01600 Reyrieux France T l 33 4 74 00 92 92 Fax 33 4 74 00 42 00 Technibel is a trademark of NIBE ENERGY SYSTEM FRANCE...

Отзывы: