ERROR

LEDS

OPERATION       TIMER            STANDBY

POSSIBLE CAUSE

SYSTEM BEHAVIOUR

SOLUTION

E4

F

F

O

Defective or not connected indoor coil 

te

mperature sensor.

Fan is stopped and flap is closed.

The system restarts automatically

 

as soon as the s

ensor is repaired.

Check that the sensor is properly

 

connected to the PCB as shown in

 

the electrical wiring diagram.

C

he

ck

 th

at

 th

e s

en

so

r i

s n

ot

 d

am

ag

ed

 

and, if nec

essary, replace it.

E5

F

O

F

Defective or not connected room air

 

temp

erature/humidity sensor.

Fan is stopped and flap is closed.

The system restarts automatically

 

as soon a

s the sensor is repaired.

Check that the sensor is properly

 

connected to the PCB as shown in

 

the electrical wiring diagram.

C

he

ck

 th

at

 th

e s

en

so

r i

s n

ot

 d

am

ag

ed

 

and,

 if necessary, replace it.

E6

O

F

F

Fan motor error.

Fan is stopped and flap is closed.

The system restarts a

utomatically

 

after some seconds.

C

he

ck

 t

ha

t t

he

 f

an

 m

ot

or

 is

 p

ro

p

er

ly

 

co

nn

ec

te

d

 to

 the

 P

C

B

 a

s s

ho

w

n i

n t

he

 

electrical wiring diagram.

Check that the fan motor is not locked.

Check that the fan motor is not

 

damag

ed and, if necessary, replace it.

E8

O

F

O

Combination between outdoor

 unit and 

indoor units is not correct.

Fan is stopped and flap is closed.

Check that you have selected, during 

the installation of the system, a proper

 

combination between outdoor unit

 

and indoor units.

Check that none of the indoor units

 

of the system has a communication

 

er

ror. If present, first solve this error.

N

o

TE: If the trouble is not solved with the above actions, contact your service centre.

O = LED OFF

 

l

 

   

= LED ON

 

F  = Flashing LED

Содержание DSA10FICR5IBA

Страница 1: ...A NOTICE D UTILISATION OPERATING INSTRUCTIONS ISTRUZIONI D USO INSTRUCCIONES DE USO BEDIENUNGSANLEITUNG Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimage...

Страница 2: ...UBLESHOOTING 10 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 14 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will need the following...

Страница 3: ...WARNING EG NAME OF PARTS AND OPERATION SELECTOR switch 5 6 7 8 9 3 10 11 2 1 4 NOTA When the unit receives a signal from the remote controller all the three lamps OPERATION TIMER and STANDBY light up...

Страница 4: ...he remote control unit and check the settings of the four microswitches as shown below TEMPERATURE SENSOR SELECTOR l Under normal conditions the room temperature is detected and checked by the tempera...

Страница 5: ...THE TIMER IFEEL IFEEL C SENSOR SELECTOR Press this button to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan...

Страница 6: ...SHOW THE ROOM TEMPERATURE AGAIN 3 Press the FAN selector button to the setting you want During Automatic Operation IFEEL ON the set temperature is understood as perceived one then the system is automa...

Страница 7: ...es the operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating...

Страница 8: ...utton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit...

Страница 9: ...has troubles follow the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode COOL or HEAT OPE...

Страница 10: ...ble the air conditioner does not run at all Possible cause 1 Power failure 2 Leakage breaker tripped 3 Operation button is OFF 4 Batteries in remote control unit have run down Remedy 1 Restore power 2...

Страница 11: ...and flap is closed The system restarts automatically as soon as the problem on the out door unit is solved Check the error code using the appro priate LEDs on the PCB of the outdoor unit Follow the in...

Страница 12: ...ck that the dip switch SW2 for communication address setting is in the correct position Check that all earth cables are properly connected to every terminal C h e c k t h a t t h e s h i e l d o f t h...

Страница 13: ...cal wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Chec...

Страница 14: ...providing this service Disposing of a battery separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to be...

Страница 15: ...Z I Route d partementale 28 01600 Reyrieux France T l 33 4 74 00 92 92 Fax 33 4 74 00 42 00 Technibel is a trademark of NIBE ENERGY SYSTEM FRANCE...

Отзывы: