7
Symbol of indoor unit SEE OUTDOOR UNIT INSTALLATION INSTRUCTION
Power Source
220 – 240 V ~ 50 Hz
Cooling
Max.Capacity
kW
10.5
BTU/h
36,200
Indoor unit(s)
A + B
C1 + C2
A + B + C1 + C2
Capacity
kW
5.50
5.00
105
BTU/h
19000
17100
36200
Voltage rating
V
230
Available voltage range
V
198 to 264
Running amperes
A
10.9 9.2 19
Power input
W
2350 2000 4080
Power factor
%
94
94
93
C.O.P.
W/W
2.4 2.5 2.6
Compressor locked rotor amperes
A
46
43
89
Fan speed
2
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment
g
R407c / A + B : 1,300 C1 + C2 : 1,200
Refrigerant control
Capillary tube
Operation sound
dB-A
54
Refrigerant tubing connections
Flare type
Max. allowable tubing length at shipment
m
A + B : 15 C1 + C2 : 15
Refrigerant tube
Narrow tube
mm (in.)
A , B , C1 , C2 : 6.35 (1/4)
diameter
Wide tube
mm (in.)
A , B , C1 , C2 : 9.52 (3/8)
Refrigerant tube kit
Optional
Dual system kit Optional (DKR8585C)
GRV340M3C5 DKR8585C
Unit dimensions
Height
mm
1,235
444
Width
mm
940
213
Depth
mm
340
118
Package dimensions
Height
mm
1,343
170
Width
mm
1,036
340
Depth
mm
421
528
Weight
Net
kg
108.0
5.0
Shipping
kg
116.0
6.0
Shipping volume
m
3
0.59
0.031
Dimensions & Weight
Features
Electrical Rating
Performance
Outdoor Unit GRV340M3C5 with DKR8585C (Option)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Содержание DKR5555C
Страница 20: ...GRV227M3C5 UNTIL31 12 2003 GRV340M3C5 FROM31 12 2003 5 2 ELECTRICWIRINGDIAGRAM SYSTEMWIRINGDIAGRAM 20...
Страница 21: ...GRV340M3C5 ELECTRICWIRINGDIAGRAM 21...
Страница 22: ...22 Outdoor Unit DKR5555C UNTIL 31 12 2002 Outdoor Unit DKR5555C FROM 01 01 2003...
Страница 23: ...23 Outdoor Unit DKR8585C UNTIL 31 12 2003 Outdoor Unit DKR8585C FROM 01 01 2003...