5
Symbol of indoor unit SEE OUTDOOR UNIT INSTALLATION INSTRUCTION
Power Source
220 – 240 V ~ 50 Hz
Cooling
Max.Capacity
kW 5.6
BTU/h
20000
Indoor unit(s)
A + B
C1 + C2
A + B + C1 + C2
Capacity
kW
3
2.85
5.60
BTU/h
10900
10000
20000
Voltage rating
V
230
Available voltage range
V
198 to 264
Running amperes A 5 5 9.6
Power input
W
1100 1100 2100
Power factor
%
95 95 95
C.O.P.
W/W
2.7 2.6 2.7
Compressor locked rotor amperes
A
24 24 48
Fan speed
1
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment
g
R407c / A + B :950 C1 + C2 :950
Refrigerant control
Capillary tube
Operation sound
dB-A
54
Refrigerant tubing connections
Flare type
Max. allowable tubing length at shipment
m
A + B : 15 C1 + C2 : 15
Refrigerant tube
Narrow tube
mm (in.)
A , B , C1 , C2 : 6.35 (1/4)
diameter
Wide tube
mm (in.)
A , B , C1 , C2 : 9.52 (3/8)
Refrigerant tube kit
Optional
Dual system kit Optional (DKR5555C)
GRV227M3C5 DKR5555C
Unit dimensions
Height
mm
630
414
Width
mm
830
213
Depth
mm
305
118
Package dimensions
Height
mm
713
170
Width
mm
994
340
Depth
mm
413
528
Weight
Net
kg
61.0
5.0
Shipping
kg
66.0
6.0
Shipping volume
m
3
0.29
0.031
Dimensions & Weight
Features
Electrical Rating
Performance
Outdoor Unit GRV227M3C5 with DKR5555C Option)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Содержание DKR5555C
Страница 20: ...GRV227M3C5 UNTIL31 12 2003 GRV340M3C5 FROM31 12 2003 5 2 ELECTRICWIRINGDIAGRAM SYSTEMWIRINGDIAGRAM 20...
Страница 21: ...GRV340M3C5 ELECTRICWIRINGDIAGRAM 21...
Страница 22: ...22 Outdoor Unit DKR5555C UNTIL 31 12 2002 Outdoor Unit DKR5555C FROM 01 01 2003...
Страница 23: ...23 Outdoor Unit DKR8585C UNTIL 31 12 2003 Outdoor Unit DKR8585C FROM 01 01 2003...