IMPORTANT!
Please read before installation

This air conditioning system meets strict safety and operating
standards.
For the installer or service person, it is important  to install or
service the system so that it operates safely and efficiently.

For safe installation and trouble-free operation, you must:

• Carefully read this instruction booklet before beginning.
• Follow each installation or repair step exactly as shown.
• Observe all local, state and national electrical  codes.
• Pay close attention to all warning and caution notices given in

this manual.

•The unit must be supplied with a dedicated electrical line.

This symbol refers to a hazard or unsafe practice which can result
in severe personal injury or death.

This symbol refers to a hazard or unsafe practice which can result
in personal injury or product or property damage.

If necessary, get help

These instructions are all you need for most installation sites and
maintenance conditions.
If you require help for a special problem, contact our sale/service
outlet or your certified dealer for additional instructions.

In case of improper installation

The manufacturer shall in no way be responsible for improper
installation or maintenance service, including failure to follow the
instructions in this document.

SPECIAL PRECAUTIONS

• During installation, connect before the refrigerant system and

then the wiring one; proceed in the reverse orden when removing
the units.

When wiring

ELECTRICAL SHOCK CAN CAUSE SEVERE
PERSONAL INJURY OR DEATH. ONLY A QUALIFIED,
EXPERIENCED ELECTRICIANS SHOULD ATTEMPT
TO WIRE THIS SYSTEM.

• Do not supply power to the unit until all wiring and tubing are

completed or reconnected and checked, to ensure the grounding.

• Highly dangerous electrical voltages are used in this system.

Carefully refer to the wiring diagram and these instructions when
wiring.
Improper connections and inadequate grounding can cause

accidental injury and death

.

Ground the unit 

following local electrical codes.

• The Yellow/Green wire cannot be used for any connection

different from the ground connection.

• Connect all wiring tightly. Loose wiring may cause overheating

at connection points and a possible fire hazard.

• Do not allow wiring to touch the refrigerant tubing, compressor,

or any moving parts of the fan.

• Do not use multi-core cable when wiring the power supply and

control lines. Use separate cables for each type of line.

When transporting

Be careful when picking up and moving the indoor and outdoor
units. Get a partner to help, and bend your knees when lifting to
reduce strain on your back. Sharp edges or thin aluminium fins on
the air conditioner can cut your fingers.

When installing...
... In a ceiling or wall

Make sure the ceiling/wall is strong enough to hold the unit-weight.
It may be necessary to build a strong wooden or metal frame to
provide added support.

... In a room

Properly insulate any tubing run inside a room to prevent
"sweating", which can cause dripping and water damage to walls
and floors.

... In moist or uneven locations

Use a raised concrete base to provide a solid level foundation for
the outdoor unit.
This prevents damage and abnormal vibrations.

... In area with strong winds

Securely anchor the outdoor unit down with bolts and a metal
frame. Provide a suitable air baffle.

... In a snowy area (for heat pump-type systems)

Install the outdoor unit on a raised platform that is higher than
drifting snow. Provide snow vents.

When connecting refrigerant tubing

• Keep all tubing runs as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of the flare

and union tubes before connecting them;  screw by hand and
then tighten the nut with a torque wrench for a leak-free
connection.

• Check carefully for leaks before starting the test run.

NOTE:

Depending on the system type, liquid and gas lines may be either
narrow or wide. Therefore, to avoid confusion, the refrigerant
tubing for your particular model is specified as narrow tube for
liquid, wide tube for gas.

When servicing

• Turn the power OFF at the main power board  before opening

the unit to check or repair electrical parts and wiring.

• Keep your fingers and clothing away from any moving parts.
• Clean up the site after the work, remembering to check that no

metal scraps or bits of wiring have been left inside the unit being
serviced.

• Ventilate the room during the installation or testng the refrigeration

system; make sure that, after the installation, no gas leaks are
present, because this could produce toxic gas and dangerous
if in contact with flames or heat-sources.

WARNING

CAUTION

WARNING

2

Содержание MPAF129R5IAA

Страница 1: ...OOR UNIT MRAF99R5IAA MRAF129R5IAA MPAF99R5IAA MPAF129R5IAA SPLIT SYSTEM AIR CONDITIONER Model No Product Code No MRAF99R5IAA 38 7104 065 MRAF129R5IAA 38 7104 062 MPAF99R5IAA 38 7104 065 MPAF129R5IAA 3...

Страница 2: ...ing to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of line When...

Страница 3: ...5 12 I Feel Function 20 5 13 Hi Power mode 20 5 14 Night Function 21 5 15 Leds off function 21 5 16 Capacity Test Mode 21 5 17 Diagnostic 22 5 18 Indoor unit jumpers Configuration 23 5 19 Outdoor unit...

Страница 4: ...de tube mm in Refrigerant Refrigerant tube kit Air clean filter Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg S...

Страница 5: ...gerant Refrigerant tube kit Air clean filter Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 D...

Страница 6: ...ces Type Operating temp Open C Close Run capacitor F VAC Flap Motor Type Model Rating Coil resistance Ambient temp 25 C Heat Exch Coil Coil Rows Fin pitch mm Face area DATA SUBJECT TO CHANGE WITHOUT N...

Страница 7: ...ng temp Open C Close Run capacitor F VAC Flap Motor Type Model Rating Coil resistance Ambient temp 25 C Heat Exch Coil Coil Rows Fin pitch mm Face area DATA SUBJECT TO CHANGE WITHOUT NOTICE BRN WHT 56...

Страница 8: ...IAA Trasformer TR Rating Primary Secondary Capacity Coil resistance at 25 C Thermal cut off temp Thermistor Coil sensor Resistance k Thermistor Room sensor Resistance k NTC THERMISTOR 10 at 25 C NTC T...

Страница 9: ...2 DIMENSIONAL DATA MRAF99R5IAA MRAF129R5IAA 9...

Страница 10: ...2 DIMENSIONAL DATA MPAF99R5IAA MPAF129R5IAA 10...

Страница 11: ...ir temp 20 C Fan speed High Heating Horizontal distance m Axis air verocity m s Vertical distance m Room air temp 27 C Fan speed High Cooling 0 1 2 3 4 0 1 2 3 4 5 6 7 8 9 Flap angle 0 Axis air veloci...

Страница 12: ...High Heating Horizontal distance m Axis air verocity m s Vertical distance m Room air temp 27 C Fan speed High Cooling 0 1 2 3 4 0 1 2 3 4 5 6 7 8 9 Flap angle 0 Axis air velocity 0 Flap angle 30 Axis...

Страница 13: ...4 ELECTRICAL DATA 4 1 Electric Wiring Diagrams MRAF99R5IAA MRAF129R5IAA MPAF99R5IAA MPAF129R5IAA 13...

Страница 14: ...a button is pressed and in any case automatically every 5 minutes 5 1 1 control specification During operation compressor speed can be subjected to change due to thermal load variations or protection...

Страница 15: ...n change speed only after it has operated at the same speed for 30 sec if in AUTO and 1 sec for the other settings High Med Low 5 3 Heat Mode Operation The Heating mode operation is similar to the Coo...

Страница 16: ...s is according to the above graph and following table If 3 C Dt 1 C and the compressor is off for more than 1 hour If Dt 3 C and compressor is off for more than 3 minutes If 1 C Dt 3 C and the compres...

Страница 17: ...1 C LEVEL 2 FMO switches 9 minutes off and 3 minutes ON 15 C FMI switches between L and LL every 30 seconds RV off CM off 15 C DRY OFF ZONE FMO off FMI off RV off SPT Set Point Temperature 5 6 Fan Mo...

Страница 18: ...s activated as soon as the indoor coil temperature ICT decreases and acts by decreasing the compresor speed The system exit this protection routine when ICT temperature rises above 8 C 5 9 2 Cold draf...

Страница 19: ...ting The module temperature detected by a built in thermistor is always monitored by the control system and kept operating in a safe area If temperature exceeds 100 C operation is automatically stoppe...

Страница 20: ...s active System exits defrost protection as soon as 14 C on the outdoor coil are detected and in any case if at least 12 minutes are elapsed from the start of the defrost cycle 5 12 I FEEL function As...

Страница 21: ...e than 5 seconds the IFEEL and FAN buttons on the remote controller With this option active the OPERATION TIMER and STANDBY lamps are switched off even during operation they activates only in case of...

Страница 22: ...M FMO FMI etc if in OFF state does not start Priority INDOOR UNIT FAULT LD1 stby LD2 opr LD3 timer 4 RAT probe damaged F F O 3 ICT probe damaged O F F 2 communication error F F F 1 fault on outdoor un...

Страница 23: ...5 18 INDOOR UNIT JUMPERS CONFIGURATION Unit is shipped with jumpers set according to the following table JUMPER STATUS JP1 open JP2 open 23...

Страница 24: ...5 19 OUTDOOR UNIT JUMPERS CONFIGURATION Unit is shipped with jumpers set according to the following table models GRF99R5IAA GRF129R5IAA JUMPER STATUS JP1 open JP2 closed JP3 open 24...

Страница 25: ...OSED system operates in the normal way according to the inputs coming from wireless remote controller 5 20 2 OUTPUT CONTACT J20 This connector is directly tied to the contact normally open of a power...

Страница 26: ...e controller The PCB settings must match the corresponding ones on the wireless remote controller How to change address of the air conditioner Set the PCB to the address desidered UNIT ADDRESS 1 2 1 o...

Страница 27: ...er is being supplied WARNING If the following troubleshooting must be done with power supplied be careful not to touch any uninsulated live part that can cause electric shock 6 2 CIRCUIT BREAKER TRIPS...

Страница 28: ...6 3 SYSTEM DOES NOT RUN 28...

Страница 29: ...6 3 SYSTEM DOES NOT RUN 29...

Страница 30: ...6 4 OUTDOOR UNIT DOES NOT RUN AND NO FAULT IS DISPLAIED 6 5 ONLY OUTDOOR UNIT IS OFF 30...

Страница 31: ...6 6 OUTDOOR UNIT FAULT SIGNALING 31...

Страница 32: ...air filters Check the air filters Are they clogged YES NO Check the expansion valve coil Is it rightly connected and the resistance value correct Replace the expansion valve coil NO There is the possi...

Страница 33: ...3 CHECK MODE BUTTON OPERATION ON THE UNIT Push the mode button The unit does not run PCB assy is defective 33...

Страница 34: ...6 8 NOISY PROBLEM 34...

Страница 35: ...7 CHECKING ELETRICAL COMPONENTS 7 1 35...

Страница 36: ...7 2 36...

Страница 37: ...0 8180 582 00 05 2009 R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France T l 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728 37...

Отзывы: