4
2-2-2. Outdoor Unit
Outdoor Unit GR128R5
Controller PCB POW-C96GH
Compressor
Type Rotary (Hermetic)
Compressor model C-R110H5H 80619445-S
Nominal output W 1,100
Compressor oil ... Amount cc SUNISO 4GSD-T ... 550
Coil resistance (Ambient temp. 25°C)
Ω
C–R : 1.962
C–S : 5.38
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA98596-9201 CS-7C115
Operating temp. Open °C 145±5 115±3
Close °C 69±11 95±5
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 21A —
Run capacitor µF 25.0
VAC 400
Crank case heater —
Fan & Fan Motor
Type Propeller
Q'ty ... Dia. 1 ... ø400
Fan motor model ... Q'ty K35610-M01402 ... 1
No. of poles ... rpm (230 V, High) 6 ... 760
Nominal output W 20
Coil resistance (Ambient temp. 20°C)
Ω
BRN-WHT : 256±7%
YEL-WHT : 227±7%
PNK-YEL : 103±7%
Safety devices Type Internal protector
Operating temp. Open °C 150±10
Close °C Automatic reclosing
Run capacitor µF 2.0
VAC 440
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.6
Face area m
2
0.301
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.