3
2-2. Major Component Specifications
2-2-1. Indoor Unit
Indoor Unit KPA128R5
Controller PCB
Part No. POW-K126GHS-(C)
Controls Microprocessor
Control circuit fuse 250 V 3.15 A
Remote Control Unit RCS-6HPS3E
Fan & Fan Motor
Type Cross-flow
Q'ty ... Dia. and length mm 2 ... ø130 / L180
Fan motor model ... Q'ty K48407-M01596 ... 1
No. of poles ... rpm (230 V, High) 4 ... 1,160
Nominal output W 20
Coil resistance (Ambient temp. 20°C)
Ω
GRY-WHT : 314±7%
WHT-PNK : 444±7%
WHT-VLT : 98.9±7%
VLT-ORG : 98.9±7%
ORG-YEL : 223±7%
Safety devices Type Internal protector
Operating temp. Open °C 145±5
Close Automatic reclosing
Run capacitor µF 1.5
VAC 440
Flap Motor
Model M2LJ24ZE31
Rating AC 208 / 230 V, 50 / 60 Hz
No. of poles ... rpm 8 ... 2.5 / 3.0
Nominal output W 3 / 2.5
Coil resistance (Ambient temp. 20°C) k
Ω
16.45 ± 15%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.8
Face area m
2
0.192
DATA SUBJECT TO CHANGE WITHOUT NOTICE.