IX-1
Section IX - Operating Procedure
Assuming the previous installation instructions have been completed and cautions noted, and the TAV-1000
power amplifier is ready to receive a properly modulated video and audio signal, proceed with the following steps
to place the system in operation. The TAV-1000 power amplifier has been factory aligned for channel frequency
(per system specification), signal levels and optimum performance.
1. Do not apply RF drive signal to the power amplifier at this time.
2. Verify that all control and RF cables are tight and properly seated in or on the mating connector.
3. Plug the modulator or processor into AC mains (110Vac).
4. Plug the 5U combiner/filter enclosure into AC mains (110Vac).
5. On the combiner/filter enclosure switch AC rocker switch to “ON” position.
6. Verify that the combiner enclosure’s fan is on.
7. Plug the 5U power amplifier enclosures into 220V AC mains.
8. On the power amplifier, simultaneously switch the AC rocker switches to “on” position.
9. Verify that the power amplifier fans are all on.
10. Ensure that the modulator/processor is turned on and set up according to its instructions. Depress the
POWER tactile button to turn the unit on.
11. The internal soft start circuitry will turn the bias voltages off until the power supply to the amplifier pallets is
fully stable. The message on the LCD indicates when the soft start is running. Once complete, the Forward
and Reflected Power and Power Supply readings will appear on the LCD in the filter and power amplifier
enclosures.
12. After the soft start is complete, apply the RF drive signal (which still should be turned down) between the
modulator or processor and the power amplifier RF In. This ensures that the RF drive signal is applied only
after the power supply is stable and the bias voltages are applied to the amplifier.