VI-8
Enclosure Interfacing
In the event of a fault in the combiner/filter enclosure, for example high reflected power or overdriven output
levels, the power amplifier enclosures need to know that there is a fault. A DB9 cable accomplishes this by
sending a fault signal from the combiner/filter enclosure to indicate to the power amplifier enclosure that
action may need to be taken. Specifically, the shutdown circuitry on the combiner/filter enclosure’s control
PCB sends a ground signal through the DB9 to one of the optoisolated inputs on the power amplifier’s
control PCB. The power amplifier control PCB, in turn, then sends its shutdown voltage out to disable the
driver and turn off the carrier.
Remote Port
The remote port allows external control of the transmission system via the DB25 connector on each
enclosure. All functions on the remote port are simply hard-wired or paralleled to existing wiring to provide a
secondary method of control to the user, and are activated as follows:
pin 1: ground to reset microcontroller, float otherwise
pin 2: ground for 2 seconds to toggle carrier on/off, float otherwise
pin 3: common ground
pin 4: DC power supply sample