VIII-10
POWER -
Tactile button
to turn carriers on and off. To turn off, must be depressed for at least 2
seconds. Tied internally through DB9 connectors to all other POWER buttons.
NAVIGATE -
Tactile button to refresh screen after two minute screen saver times out. All monitoring
and protection continues during screen saver.
SELECT-
Tactile button to refresh screen after two minute screen saver times out. All monitoring
and protection continues during screen saver
RESET -
Tactile button to reset microcontroller in control board. Also clears existing faults.
Individual control board with reset comes back on with soft start feature.
PA1 and PA2 RF IN –
RF input from the output of each power amplifier. N connector, 50
Ω
.
RF OUT –
1,000-watt RF output to be connected with inline wattmeter and then to antenna. N
connector, 50
Ω
.
PA CTRL
–
Control signals communicating from the combiner enclosure to the power amplifier
enclosures. Connects with the PA 1 and PA 2 CTRL connector on the power amplifier.
DB9 connector (see Amplifier Monitoring section for pinout description).
REMOTE PORT -
pin 1: ground to reset microcontroller, float otherwise
pin 2: ground for 2 seconds to toggle carrier on/off, float otherwise
pin 3: common ground
pin 4: DC power supply sample
AC IN –
AC input to switching power supply. Switching power supply draws a
maximum of 2 A
AC
at 110 V
AC
.