X-2
Troubleshooting
The first and most important aspect of troubleshooting anything is to be systematic. Note where you have
looked and what you found.
Look first for the obvious.
•
Make a physical inspection of the entire facility. Are all necessary connections properly made? Do you
see any signs of obvious damage within the equipment?
•
Is the AC power ‘ON’ to the site and the equipment? (Check fuses and circuit breakers if necessary.)
•
Are all the switches in the correct operating position?
•
Is the input signal present?
•
Check LCD readings for presence of forward and reflected power and 31 V DC supply levels.
The above is an aid in determining the fault if some aspect of the system is not operating. The following table
deals with quality of operation:
Symptom
Possible Fault
Correction
Horizontal bars in picture (may roll
either way depending on phase)
AC grounding / AC interference
Install EMI/RFI filter in AC line
Ensure modulator/processor and
power amplifier share a common
ground
Diagonal lines in picture
Interference
Install EMI/RFI filter in AC line
Determine source and frequency
of interfering signal (spectrum
analyzer may be required)