3.Output Voltage TRIM
(1)Connecting an external DC source between PV and-S on CN1 or CN2 that is shown in Fig. 3.1.
(2)Adjustment of output voltage is possible between 20~110%(Typ.) of the rated output which is shown in Fig. 3.2. Reducing output current is required when the
output voltage is trimmed up.
2.Alarm Signal Output
(1)Alarm signal is sent out through "P OK" & "P OK GND" and P OK2 & P OK GND2 pins.
(2)An external voltage source is required for this function.
(3)Table 2.1 explain the alarm function built-in the power supply.
Fig. 2.2 Internal circuit of P OK (Relay, total is 10W)
Fig. 3.1 Add on 1~6V external voltage
Fig. 3.2 Output voltage trimming
External voltage and R
(The max. sink is 500mA and 20V)
P OK GND
P OK
Function
P OK
The signal is "Low" when the power supply is
80% of the rated output voltage-Power OK
above
Low (0.5V max at 500mA)
Low (0.5V max at 10mA)
Description
Output of alarm(P OK, Relay Contact)
Output of alarm(P OK2, TTL Signal)
The signal turns to be "High" when the power supply
is under 80% of the rated output voltage-Power Fail
High or open
(External applied voltage, 500mA max.)
High or open
(External applied voltage, 10mA max.)
R
V
Fig. 2.3 Internal circuit of P OK2 (Open collector method)
External voltage and R
(The max. sink is 10mA and 30V)
P OK GND2
P OK2
R
V
0.1uF
Table 2.1 Explanation of alarm
1
2
3
4
5
6
V
Vout
100
120
40
60
80
20
OUTPUT
VOL
TA
GE
(%)
EXTERNAL VOLTAGE (DC)
Non-Linear
OVP >120%
40
60
80
100
120
V
100
40
60
80
20
OUTPUT
CURRENT
(%)
OUTPUT VOLTAGE (%)
20
PV
1~6V
-S
File Name:RSP-3000-SPEC 2009-09-21
3000W Single Output Power Supply
RSP-3000
series
Содержание TAUD-100
Страница 1: ...TAUD 1000 BROADCAST TRANSMITTER OPERATING MANUAL ...
Страница 34: ......
Страница 35: ......
Страница 49: ......
Страница 50: ......
Страница 52: ...Technalogix Ltd Adrenaline Control System VI 31 Temp sensor 1 11 component layout Top ...
Страница 53: ...Technalogix Ltd Adrenaline Control System VI 32 Temp sensor 1 11 component layout bottom ...
Страница 58: ......
Страница 59: ......
Страница 62: ......
Страница 63: ......
Страница 69: ...Technalogix Ltd Adrenaline Control System VI 66 SNMP Configuration ...
Страница 75: ...Technalogix Ltd Adrenaline Control System VI 72 Shown here is trap of a high temperature fault Value 4 ...
Страница 97: ...Thank you for choosing Technalogix Ltd ...