The primary function of the Display Interface module is, as the name suggests, providing the
display and user interface for the control system. This circuit board is mounted behind the front
panel of the power amplifier enclosure(s) in the transmitter/translator, near the 4.3” touchscreen
display. All switch/settings and user interface is handled through the resistive touchscreen. The
touchscreen on the front panel is connected to the Display Interface PCB through a cable.
These components provide the user with the ability to monitor the following power amplifier
parameters from the front panel:
•
Forward (incident) power at the power amplifier output.
•
Reflected (reverse) power at the power amplifier output.
•
DC voltage of the power amplifier’s power supply.
•
DC current in the power amplifier.
•
Temperature of the heat sink of the power amplifier.
•
The time since the transmitter/translator was last shut down.
•
Full history of faults and events
•
Mode of the power amplifier (selectable between Manual and AGC).
•
Indication if there is attenuation added to the front end of the power amplifier indicating
fold back in RF power (indicates amount of attenuation)
•
Settings to change the VSWR trip point shutdown between 1.1:1 and 1.8:1.
•
Settings to change the RF power units between % power (maximum of 110%) or watts.
•
Summary of PCB modules and assembly numbers specific to the power amplifier
A block diagram of the Display Interface PCB follows:
Содержание TAUD-100
Страница 1: ...TAUD 1000 BROADCAST TRANSMITTER OPERATING MANUAL ...
Страница 34: ......
Страница 35: ......
Страница 49: ......
Страница 50: ......
Страница 52: ...Technalogix Ltd Adrenaline Control System VI 31 Temp sensor 1 11 component layout Top ...
Страница 53: ...Technalogix Ltd Adrenaline Control System VI 32 Temp sensor 1 11 component layout bottom ...
Страница 58: ......
Страница 59: ......
Страница 62: ......
Страница 63: ......
Страница 69: ...Technalogix Ltd Adrenaline Control System VI 66 SNMP Configuration ...
Страница 75: ...Technalogix Ltd Adrenaline Control System VI 72 Shown here is trap of a high temperature fault Value 4 ...
Страница 97: ...Thank you for choosing Technalogix Ltd ...