Technalogix Ltd
X-2
Troubleshooting
The first and most important aspect of troubleshooting anything is to be systematic. Note where
you have looked and what you found.
Look first for the obvious.
•
Make a physical inspection of the entire facility. Are all necessary connections properly made?
Do you see any signs of obvious damage within the equipment?
•
Is the AC power ‘ON’ to the site and the equipment? (Check fuses and circuit breakers if
necessary.)
•
Are all the switches in the correct operating position?
•
Is the input signal present?
•
Check LCD readings for presence of forward and reflected power and 31 V DC supply levels.
The above is an aid in determining the fault if some aspect of the system is not operating. The
following table deals with quality of operation:
Symptom
Possible
Fault
Correction
Horizontal bars in picture
(may roll either way
depending on phase)
AC grounding / AC
interference
Install EMI/RFI filter in AC line
Ensure
modulator/processor
and power amplifier share a
common ground
Diagonal lines in picture
Interference
Install EMI/RFI filter in AC line
Determine
source
and
frequency of interfering signal
(spectrum analyzer may be
required)
Содержание TAUD-100
Страница 1: ...TAUD 1000 BROADCAST TRANSMITTER OPERATING MANUAL ...
Страница 34: ......
Страница 35: ......
Страница 49: ......
Страница 50: ......
Страница 52: ...Technalogix Ltd Adrenaline Control System VI 31 Temp sensor 1 11 component layout Top ...
Страница 53: ...Technalogix Ltd Adrenaline Control System VI 32 Temp sensor 1 11 component layout bottom ...
Страница 58: ......
Страница 59: ......
Страница 62: ......
Страница 63: ......
Страница 69: ...Technalogix Ltd Adrenaline Control System VI 66 SNMP Configuration ...
Страница 75: ...Technalogix Ltd Adrenaline Control System VI 72 Shown here is trap of a high temperature fault Value 4 ...
Страница 97: ...Thank you for choosing Technalogix Ltd ...